17
CHAPTER 4: Configuration
2. Sub-channel parameters that affect only the operation of a single
sub-channel. Sub-channel parameters are listed in Table 4-2.
Set these parameters with the MiniStat-Four’s configuration program.
Sections 4.2
through
4.5
tell you how to use this program; the organization tree for the
program is shown in Figure 4-1.
Table 4-1. MiniStat-Four system parameters and factory settings.
No. Parameter
Function
Available
Factory
Selections
Setting
1
PASSWORD
Controls access
Any two
RD
to configuration
characters
(capital
as X-ON and
except those
letters)
X-OFF
used as X-ON
and X-OFF
control
characters
2
X-ON
When using
11H (DC1)
11H
CONTROL
software flow
12H (DC2)
CHARACTER
control, causes
13H (DC3)
the receiving
14H (DC4)
terminal to
91H
start data
92H
transfer
93H
94H
3
X-OFF
When using
Same range
13H
CONTROL
software flow
as for X-ON;
CHARACTER
control, causes
however,
the receiving
the selected
terminal to stop
character
transfer of data
must be
different from
the X-ON
character