69
C.3 Configuration Instructions
NOTE
The commands and passwords are case-sensitive. Pay attention to use
of capital letters whenever required.
1. If necessary, power up the MS-4 and connect your terminal to one of the sub-
channels. Check terminal communication parameters.
2. Allow an idle period of at least one second, type
@@@
, wait at least one more
second, and type
S
.
3. The MS-4 enters the command mode. Enter the password.
NOTE
The default password is RD. If you do not know the password, initialize
the MS-4 by means of the INIT/NOR jumper.
4. The MS-4 displays the MAIN Menu. Use Figure 4-1 to plan your configuration
actions. Record the configuration on a copy of the form given in
Appendix B
.
Keep the filled-out form for reference.
IMPORTANT
Each configuration change takes effect immediately. Each time you
change one of the communication parameters of the sub-channel you
use now, you must immediately change the corresponding
communication parameter of your terminal to the same value. If you
don’t, you lose communication with the MS-4. If you make an error that
you cannot correct, initialize the MS-4 again with the INIT/NOR jumper
and start over.
5. When the link to the remote MS-4 operates, use REMOTE SYSTEM
CONFIGURATION to transfer local configuration to remote MS-4, and/or to
configure the remote MS-4 as required.
6. If you initialized the MS-4, modify the password as required. Record the
password.
7. Exit the command mode by typing “6” at the MAIN Menu.
APPENDIX C: Quick Setup Guide