20
G.703 CODIRECTIONAL CONVERTER
3. Installation
This chapter shows you how to install the G.703 Codirectional Converter.
After you complete the installation, refer to
Chapter 4
for operating
information.
The AC-powered (IC714A and IC714AE) models of the G.703 Codirectional
Converter are designed for placement on a shelf or bench, and come
completely assembled. With a rackmount-adapter kit (not included—call for a
quote), you can also install them in a 19-inch rack.
The DC-powered (IC714A-48) model of the G.703 Codirectional Converter is
designed to operate from –48 VDC. With a rackmount adapter kit, these can
also be installed in a 19-inch rack.
3.1 Unpacking
Unpack the equipment this way:
• Carefully take the G.703 Codirectional Converter out of the box it came
in and place the Converter on a clean surface.
• Inspect the unit for damage. Immediately report any damage you find to
your carrier and to Black Box.
3.2 Site Requirements
An AC-powered G.703 Codirectional Converter should be installed within 5
feet (1.5 m) of a grounded AC outlet capable of providing 230 or 115 volts.
It must be situated within half a mile (800 m) of the PCM equipment.
A DC-powered G.703 Codirectional Converter should be installed near a
grounded DC power source capable of providing –48 volts. It must be situated
within half a mile (800 m) of the PCM equipment.
Make sure that there is at least 4 inches (10 cm) of clearance behind the
G.703 Codirectional Converter for signal lines and interface cables.