32
G.703 CODIRECTIONAL CONVERTER
Table 4-1. Functions of LEDs and Controls.
Indicator/Control
Function
PWR (Green LED)
Lights when the unit is receiving power.
Power
TD (Yellow LED)
Flickers when data is present at transmit
Transmit Data
input and goes off when a steady mark is
present.
RD (Yellow LED)
Flickers when data is present at receive
Receive Data
output and goes off when a steady mark is
present.
LOS (Red LED)
Lights when the RX pair does not contain
Loss of Signal
the violations required.
TEST (Red LED)
Lights when a loopback is performed.
Test
ERR (Red LED)
Lights when errors are detected in the test
pattern. Active only after PATT button is
pressed.
DIG (Pushbutton)
Activates local digital loopback.
ANA (Pushbutton)
Activates local analog loopback.
REM (Pushbutton)
Activates remote digital loopback.
PATT (Pushbutton)
Activates V.52-compliant pattern test.