Terminal Server User Guide
Installing the Rack Terminal Server 48V DC
Page 172
Safety Earth
Warning
This apparatus must be earthed.
A safety earth point is provided on the rear on the unit. A suitable earth cable of at least
20awg should be attached using the M3 pozi head screw and shakeproof washer to the
safety earth point on the rear of the unit.
Fusing
CAUTION: for continued protection against risk of fire, replace only with same type of and
rating of fuse.
The Rack Terminal Server 48V is fitted with a 1 Amp time delay DC rated fuse (6.3 x 32 mm).
In the event of a fuse failure, it must be replaced with an equivalent type.
Recommended fitment is Bussmann MDA1.