ENGLISH

CAUTION:  Maintenance

DISASSEMBLY

1.  Replacement parts may be available at the store where you purchased 

your faucet.

2.  When  replacement  parts  are  not  available,  please  write  or  call  Price 

Pfi ster Consumer Service.

3. 

Always turn off water and relieve pressure before working on your 

faucet.

NOTE:  Trim Care

Cleaning Instructions:

For all Handles and decorative fi nishes, use only a soft damp 

cloth to clean and shine.  Use of polish, detergents, abrasive 

cleaners, organic solvents or acid may cause damage.  

Use of 

other than a soft damp cloth will nullify our warranty!

Special Trim:

  

Trim  products  which  contain  Porcelain  or  other  similar 

substance  are  not  acceptable  for  public  areas  or  Commercial 

use.  Installation of Said Trim is at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call 

1–800–PFAUCET (1–800–732–8238) 

or visit www.pricepfi ster.com

•   Installation Support

•   Care and Warranty Information

Temperature or fl ow does not remain consistent.

The Cartridge Assembly (

D

) may need cleaning. Shut off water supply.  Unscrew 

Retainer Sleeve (

B

) and remove Flange (

C

).  Remove Cartridge assembly 

(

D

) and inspect Cartridge (

E

) and inlets for debris or sediment and fl ush with 

EE

water. Reassemble whole unit and test.  If problem persists you may need to 

replace the Cartridge (

E

).

EE

Sleeve (B) is too short.

Extension kit 910-563 is available at a nominal charge for valves which have 

been roughed-in too far back in the wall. The kit contains a one inch stem 

extension, and longer screw and a sleeve which is one inch longer than the 

972-300.

Dripping from the tub spout.

Clean the Cartridge Assembly (

D

). Check to ensure the two Oval O-Rings (

F

FF

on the back of the Cartridge (

E

) are in place. Reassemble cartridge, stem and 

EE

bonnet assembly and handle. Turn on the water and test. If the unit still leaks, 

replace the Cartridge (

E

).

EE

Make sure that both hot and cold water inlets are turned on.

Water fl ow is very low.

Check the Cartridge Assembly (

D

), for debris. Sediment where the water enters 

the Tub Spout (

H

) can also cause this symptom.

Water starts out hot and becomes cooler as handle is rotated counter

clockwise.

This is a potentially hazardous situation and should be corrected before using 

the unit. Check the hot and cold inlet positions (hot- left cold-right). If you have 

a back to back installation, (where hot and cold inlets are reversed) refer to 

Valve Body instruction sheets for back to back installation.

Water doesn’t get hot enough.

Remove Sleeve (

B

) and Flange (

C

) and then refer to Valve Body instruction 

sheets for adjusting temperature range.

MAINTENANCE & CARE

TROUBLE SHOOTING TIPS

4

B

C

G

E

F

J

D

Summary of Contents for Price Pfister Portland R89-5 Series

Page 1: ...asos podría pedírsele devolver el Producto a Price Pfister para su inspección y es posible que se requiera la presentación de una prueba de compra Limitaciones y Exclusiones Limitaciones y Exclusiones PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO Limitaciones y Exclusiones PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO Li...

Page 2: ...lant Philips head screwdriver Adjustable wrench Pipe wrench Flashlight Cloth Your installation will require a pipe nipple for the spout installation as well as other additional tools 4 CHECKING THE CONTENTS OF THE BOX Upon opening the box check to ensure that all of the following items are included A Gasket Flange B Trim Flange C Washer D Retainer Sleeve E Spout If any of these items are missing p...

Page 3: ...The Pipe Nipple 9A 9A 9 is to project 6 9 16 to 6 11 16 from the finished wall Remove Internal Connector 9E from Spout 9C Screw Tub Spout 9C onto Pipe Nipple 9A 9A 9 and tighten until Spout is properly positioned and flush to the finished wall 11 VALVE FUNCTION By rotating the Handle 11A slightly counterclockwise the valve will be fully activated to the COLD position The water temperature can be incr...

Page 4: ...Reassemble whole unit and test If problem persists you may need to replace the Cartridge E E E Sleeve B is too short Extension kit 910 563 is available at a nominal charge for valves which have been roughed in too far back in the wall The kit contains a one inch stem extension and longer screw and a sleeve which is one inch longer than the 972 300 Dripping from the tub spout Clean the Cartridge As...

Page 5: ...e quite la unidad existente y limpie completamente la superficie de montaje 3 HERRAMIENTAS RECOMENDADAS Cinta para plomería PTFE o sello para roscas Destornillador en cruz Llave ajustable Llave para tuberías Linterna de mano Paño Para instalar el conducto se necesita un acoplador para tuberías así como otras herramientas adicionales 4 REVISIÓN DEL CONTENIDO DE LA CAJA Luego de abrir la caja verifiqu...

Page 6: ...l conectador interno 9E del conducto de la Tina 9C Enrosque el conducto de la tina 9C en el acoplador de la tubería 9A 9A 9 y apriételo hasta que el conducto quede colocado adecuadamente y al ras con la pared terminada 10 ACTIVACIÓN DE LA UNIDAD Active el suministro de agua fría así como el de agua caliente verifique que no hay fugas 11 FUNCIONAMIENTO DE LA VÁLVULA hay fugas 11 FUNCIONAMIENTO DE LA...

Page 7: ...ruébela Si el problema continúa podría ser necesario reemplazar el cartucho E E E El manguito B es muy corto Para las válvulas que han sido colocadas muy dentro de la pared se encuentra disponible el juego para extensión 910 563 a costo nominal El juego contiene una extensión de una pulgada para el vástago tornillos más largos y un manguito que es una pulgada más largo que el 972 300 El conducto d...

Page 8: ...r les arrivées d eau et fermer leurs robinets Ces robinets se trouvent généralementàcôtéducompteurd eau Encasderemplacementd unegarniture existante la déposer et nettoyer soigneusement la surface de montage 3 OUTILLAGE RECOMMANDÉ Ruban PTFE de plombier ou mastic d étanchéité de filetage Tournevis cruciforme Clé à molette Clé serre tube Lampe de poche Chiffon L installation exige un manchon fileté po...

Page 9: ...n fileté 9A 9A 9 et le serrer jusqu à ce qu il soit dans et le serrer jusqu à ce qu il soit dans la position correcte contre le mur fini 10 MISE EN SERVICE DE L APPAREIL Ouvrir les arrivées d eau chaude et d eau froide et contrôler l étanchéité de Ouvrir les arrivées d eau chaude et d eau froide et contrôler l étanchéité de tous les branchements 11 FONCTIONNEMENT DU MITIGEUR Lorsqu on tourne légèrem...

Page 10: ...tiellementdangereuseetdoitêtrecorrigéeavantl utilisation du mitigeur Vérifier la position des arrivées d eau chaude et d eau froide chaud gauche froid droite En cas d installation dos à dos dans laquelle les arrivées d eau chaude et d eau froide sont interverties se reporter aux fiches d instructions relatives au corps de mitigeur pour ce type d installation 1 800 PFAUCET 1 800 732 8238 Pour les ren...

Page 11: ...FRANÇAIS FRAN FRAN 11 ...

Page 12: ...gnates Finish Letter Designates Finish La Letra Indica el Terminado La Letra Indica el Terminado La Lettre Designe La Fini La Lettre Designe La Fini A Polished Chrome Cromo Pulido Chrome Poli E Rustic Pewter Peltre Rústico Étain Rustique J PVD Brushed Nickel PVD Niquel Cepillado PVD Nickel Brosse U Rustic Bronze Bronce Rústico Bronze Rustique Y Tuscan Bronze Bronce Toscano Bronze Le Toscan Z Oil R...

Reviews: