8   TRIM FLANGE ATTACHMENT

Position Flange (

8A

88

) on Valve (

8B

) with Drain Hole (

8C

) at the bottom.  Place 

Protective Washer (

8D

) on the short end of the reversible Retainer Sleeve (

8E

).  

EE

Screw Retainer Sleeve (

8E

) onto threaded section of the Stem and Bonnet (

EE

8G

).  

Tighten Retainer Sleeve (

8E

) by hand until Flange (

EE

8A

88

) is snug to fi nished wall 

surface.  If the short end of the Retainer Sleeve (

8E

) is too short, reverse it to 

EE

use the longer end.

9   SPOUT INSTALLATION

A.  For Copper Pipe Connections:

Connect Copper Tube (

9A

99

) into the elbow inside the wall and remove the sharp 

edges all around the outer tube (

9B

). The Copper Tube (

9A

99

) is to project 5

3

/

8

” 

to 5 

7

/

8

” from the fi nished wall. Slide Tub Spout (

9C

) onto Pipe Nipple (

9A

99

) until 

spout is properly positioned and fl ush to the fi nished wall surface. Tighten Set 

Screw (

9D

) located at the bottom of spout.

B.  For  Threaded Iron Pipe Connections:

Apply PTFE plumbers tape on both ends of Pipe Nipple (

9A

99

) (not included).  

Screw Pipe Nipple (

9A

99

) into the elbow inside the wall and tighten with pipe 

wrench. The Pipe Nipple (

9A

99

) is to project 6 

9

/

16

” to 6 

11

/

16

” from the fi nished 

wall.  Remove Internal Connector (

9E

) from Spout (

9C

). Screw Tub Spout 

(

9C

) onto Pipe Nipple (

9A

99

) and tighten until Spout is properly positioned and 

fl ush to the fi nished wall.

11   VALVE FUNCTION

By rotating the Handle (

11A

) slightly counterclockwise, the valve will be fully 

activated to the “COLD” position. The water temperature can be increased by 

continuing to rotate the Lever Handle (

11A

) in a counterclockwise direction.

12   FINAL FLUSHING

For fi nal fl ushing, turn valve on and allow water to run through the Tub Spout (

12A

for several minutes.  Allow water to run until all foreign matter clears the line.

7   TUB ONLY OUTLET CONNECTIONS

Connect Tub Outlet Pipe (

7A

) to valve body (

7B

).  Plug top outlet (

7C

) with  

Pipe Cap (

7D

).  Connect Pipe Elbow (

7E

) (not included) to the end of the pipe.  

For copper pipe outlets, we recomend using drop elbows (

7E

) (not included). 

Screw holes (

7F

) are provided to secure the elbow to framing or other solid 

support.  

WARNING

 Iron Pipe Connections:

When attaching threaded fi ttings, use thread sealant or PTFE Plumber’s tape 

according to manufacturer’s instructions.

10  UNIT START UP

Turn on hot and cold water supplies, and check all connections for leaks.

8

9

11

12

7

3

8A

8B

8C

8C

8D

8E

8G

9A

6

9

/

16

” to 6

11

/

16

9B

5

3

/

8

” to 5

7

/

8

9C

9D

A

B

9A

9E

9C

FULL HOT

FULL COLD

CLOSED

OPEN

11A

12A

12A

7D

7E

7A

7C

7B

7F

Summary of Contents for Price Pfister Portland R89-5 Series

Page 1: ...asos podría pedírsele devolver el Producto a Price Pfister para su inspección y es posible que se requiera la presentación de una prueba de compra Limitaciones y Exclusiones Limitaciones y Exclusiones PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO Limitaciones y Exclusiones PRICE PFISTER NO SE HARÁ RESPONSABLE DE NINGÚN OTRO DAÑO Li...

Page 2: ...lant Philips head screwdriver Adjustable wrench Pipe wrench Flashlight Cloth Your installation will require a pipe nipple for the spout installation as well as other additional tools 4 CHECKING THE CONTENTS OF THE BOX Upon opening the box check to ensure that all of the following items are included A Gasket Flange B Trim Flange C Washer D Retainer Sleeve E Spout If any of these items are missing p...

Page 3: ...The Pipe Nipple 9A 9A 9 is to project 6 9 16 to 6 11 16 from the finished wall Remove Internal Connector 9E from Spout 9C Screw Tub Spout 9C onto Pipe Nipple 9A 9A 9 and tighten until Spout is properly positioned and flush to the finished wall 11 VALVE FUNCTION By rotating the Handle 11A slightly counterclockwise the valve will be fully activated to the COLD position The water temperature can be incr...

Page 4: ...Reassemble whole unit and test If problem persists you may need to replace the Cartridge E E E Sleeve B is too short Extension kit 910 563 is available at a nominal charge for valves which have been roughed in too far back in the wall The kit contains a one inch stem extension and longer screw and a sleeve which is one inch longer than the 972 300 Dripping from the tub spout Clean the Cartridge As...

Page 5: ...e quite la unidad existente y limpie completamente la superficie de montaje 3 HERRAMIENTAS RECOMENDADAS Cinta para plomería PTFE o sello para roscas Destornillador en cruz Llave ajustable Llave para tuberías Linterna de mano Paño Para instalar el conducto se necesita un acoplador para tuberías así como otras herramientas adicionales 4 REVISIÓN DEL CONTENIDO DE LA CAJA Luego de abrir la caja verifiqu...

Page 6: ...l conectador interno 9E del conducto de la Tina 9C Enrosque el conducto de la tina 9C en el acoplador de la tubería 9A 9A 9 y apriételo hasta que el conducto quede colocado adecuadamente y al ras con la pared terminada 10 ACTIVACIÓN DE LA UNIDAD Active el suministro de agua fría así como el de agua caliente verifique que no hay fugas 11 FUNCIONAMIENTO DE LA VÁLVULA hay fugas 11 FUNCIONAMIENTO DE LA...

Page 7: ...ruébela Si el problema continúa podría ser necesario reemplazar el cartucho E E E El manguito B es muy corto Para las válvulas que han sido colocadas muy dentro de la pared se encuentra disponible el juego para extensión 910 563 a costo nominal El juego contiene una extensión de una pulgada para el vástago tornillos más largos y un manguito que es una pulgada más largo que el 972 300 El conducto d...

Page 8: ...r les arrivées d eau et fermer leurs robinets Ces robinets se trouvent généralementàcôtéducompteurd eau Encasderemplacementd unegarniture existante la déposer et nettoyer soigneusement la surface de montage 3 OUTILLAGE RECOMMANDÉ Ruban PTFE de plombier ou mastic d étanchéité de filetage Tournevis cruciforme Clé à molette Clé serre tube Lampe de poche Chiffon L installation exige un manchon fileté po...

Page 9: ...n fileté 9A 9A 9 et le serrer jusqu à ce qu il soit dans et le serrer jusqu à ce qu il soit dans la position correcte contre le mur fini 10 MISE EN SERVICE DE L APPAREIL Ouvrir les arrivées d eau chaude et d eau froide et contrôler l étanchéité de Ouvrir les arrivées d eau chaude et d eau froide et contrôler l étanchéité de tous les branchements 11 FONCTIONNEMENT DU MITIGEUR Lorsqu on tourne légèrem...

Page 10: ...tiellementdangereuseetdoitêtrecorrigéeavantl utilisation du mitigeur Vérifier la position des arrivées d eau chaude et d eau froide chaud gauche froid droite En cas d installation dos à dos dans laquelle les arrivées d eau chaude et d eau froide sont interverties se reporter aux fiches d instructions relatives au corps de mitigeur pour ce type d installation 1 800 PFAUCET 1 800 732 8238 Pour les ren...

Page 11: ...FRANÇAIS FRAN FRAN 11 ...

Page 12: ...gnates Finish Letter Designates Finish La Letra Indica el Terminado La Letra Indica el Terminado La Lettre Designe La Fini La Lettre Designe La Fini A Polished Chrome Cromo Pulido Chrome Poli E Rustic Pewter Peltre Rústico Étain Rustique J PVD Brushed Nickel PVD Niquel Cepillado PVD Nickel Brosse U Rustic Bronze Bronce Rústico Bronze Rustique Y Tuscan Bronze Bronce Toscano Bronze Le Toscan Z Oil R...

Reviews: