7

N o t e :

Make sure all other unit functions are turned OFF during recharging, as this can slow the recharging
p r o c e s s .

120 Volt AC Charging Method

The 120 Volt AC Charging Adapter is a UL listed “wall” type unit that operates from any 120 volt, 60 Hz AC supply
that has a standard North American outlet. The adapter has a barrel connector that plugs into the unit’s 12 Vo l t
Recharging Port. Make sure the Jump-Starter Power Switch and Area Light Power Switch are turned OFF during
AC charging/recharging. When the 120 Volt AC Charging Adapter is plugged into the 12 Volt DC Recharging Port,
the Battery Charge Status LED Indicators will automatically light. As recharge progresses, the red LEDs will light,
one by one. Charge the unit until the three red and one green LED indicators are lit. Continue to recharge for one
to two hours, then disconnect the Charging Adapter.

N o t e :

The unit cannot be overcharged using this method.

12 Volt DC Charging Method

Charging the Jump-Starter/Inflator from an external 12 volt DC power source requires the use of the 12 Volt DC
a d a p t e r. This adapter has a male DC connector at each end.
Unlike the AC recharge method, DC recharge does NOT automatically activate the Battery Status LED display.
B a t t e ry status can still be monitored by pressing the Battery Status Pushbutton.

1 .Insert the gold-tipped 12 Volt DC Charging Adapter plug into the vehicle’s 12 volt DC accessory outlet.
2 .Insert the silver-tipped end plug into the 12 volt DC accessory outlet on the front panel of the unit.
3 .Charge the unit until the green FULL indicator lights when the battery status level pushbutton is pressed. DO

NOT EXCEED 4 HOURS MAXIMUM.

4 .When charging is complete, remove the charging cord and store in a safe place.

C A U T I O N S :

• To reduce the risk of property damage, do not  leave the unit unattended while charging using this method.
• To reduce the risk of shortening the life of the battery; do not recharge the unit using the DC method for more

than 4 hours.

N o t e s :

Make sure all functions are turned OFF during recharge as this may slow the recharging process.
Some vehicles require that the ignition be switched to the accessory outlet position in order to power the
a c c e s s o ry outlet.

Viewing Battery Charge Status

Press the Battery Status Pushbutton located on the unit’s front panel. The four LEDs that make up the Battery
Status Display will light according to the unit’s level of charge, where one light indicates the unit requires
recharging and all four lit indicates that the unit is fully charged and ready to operate.

JUMP-STARTER

This Jump-Starter is equipped with an ON/OFF Power Switch. Once the connections are properly made, turn the
switch ON to jump-start the vehicle.

1 .Turn OFF vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place

vehicle in “park” and set the emergency brake. 

2 .Make sure the Jump-Starter Power Switch is turned to OFF.
3 .Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp. 
4 .Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to

chassis) (MOST C O M M O N )

4 a .Connect P O S I T I V E (+) R E D clamp to vehicle battery ’s positive terminal.
4 b .Connect N E G AT I V E (–) B L A C K clamp to chassis or a solid, non-moving, metal vehicle component or

body part. Never clamp directly to N E G AT I V E b a t t e ry terminal or moving part. Refer to the automobile
u s e r ’s manual.

5 .Procedure for jump-starting POSITIVE GROUND SYSTEMS

N o t e :

In the rare event that the vehicle to be started has a Positive Grounded System (positive battery
terminal is connected to chassis), replace steps 4a and 4b above with steps 5a and 5b, then proceed
to step 6.

120 VOLT AC

C H A R G I N G

A D A P T E R

12 VOLT DC 
C H A R G I N G
A D A P T E R

6

Controls and Indicators

Applications

• Jump-start most vehicle batteries with a standard 12 volt DC system: small truck, car, RV, tractor, etc. 
• Operate (using 5 amp rated 12 volt DC accessory outlet): 12 volt DC fans, fluorescent worklights, air inflators,

spotlights, TVs, portable radios, cassette or CD players, and more. The unit can quick-charge a cellular phone
by using the phone’s 12 volt DC adapter cord. 

• Illuminate areas under the hood, inside tents and work areas.
• Inflate (using inflator) tires, air mattresses, basketballs, volleyballs, and more.

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose
energy from self-discharge over time and more rapidly when they are at higher temperatures. Therefore, batteries
need periodic charging to replace energy lost through self-discharge. When the unit is not in frequent use, Black
& Decker recommends the battery be recharged at least every 60 days.
Check the battery charge level by pressing the battery status button. The LED charge status display will indicate
the level of battery charge. When only one red LED lights, recharge the unit.

N o t e s :

This unit is delivered in a partially charged state – you must fully charge it before using it for the first time.
Initial AC charge should be for 24 hours.
Recharging battery after each use will prolong battery life; frequent heavy discharges between recharges
and/or overcharging will reduce battery life. The battery can be recharged using either the AC or DC
Charging Adapter (see below).

NOZZLES

1 . Built-in LED Area Light
2. Charging Port for 120 Volt AC Charging

A d a p t e r

3 . Alternator Check Indicator
4 . 12 Volt DC Outlet
5 . LED Battery Status Indicators
6 . B a t t e ry Charge Level Pushbutton
7 . Jump-Starter Power Switch

8 . Reverse Polarity Indicator
9. Area Light Power Switch

1 0 . Air Pressure Gauge
1 1 . Inflator Power Switch 
1 2 . Positive (+) Red Clamp 
1 3 . Negative (–) Black Clamp
1 4 . Air Hose
1 5 . Connector (Chuck)

Front View

Back View

2

3

4

5

10

11

15

14

12

13

9

6

1

7

8

JU300CB ManualENSP 072208.qxp  9/26/08  12:47 PM  Page 6

Summary of Contents for 300 AMP JUMP-STARTER/INFLATOR

Page 1: ...ASE CALL 1 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER SAVE THIS MANUAL FOR FUTURE REFERENCE Cat JU300CB Form 90521848 July 2008 Copyright 2008 Black Decker Printed in China JU300CB ManualENSP 07220...

Page 2: ...NS DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without thesafety alertsymbol indicates potentia...

Page 3: ...n a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle parts Never allow RED andBLACK clamps to touch each other or another common metalconductor this could cause damage to the unit and or create a sparking explosion hazard a For negative grounded systems connect the POSITIVE RED clamp to the POSITIVE ungrounded battery post and the NEGATIVE B...

Page 4: ...s etc Place vehicle in park and set the emergency brake 2 Make sure the Jump Starter Power Switch is turned to OFF 3 Remove jumper clamps from clamp tabs Connect the red clamp first then the black clamp 4 Procedure for jump starting aNEGATIVE GROUNDED SYSTEM negative battery terminal is connected to chassis MOST COMMON 4a ConnectPOSITIVE RED clamp to vehicle battery s positive terminal 4 b Connect...

Page 5: ...vehicle component or body part Never clamp directlytoPOSITIVE batteryterminal or moving part Refer to the automobile user s manual 6 When clamps are connected properly turn the Jump Starter Power Switch to ON 7 Turn ON the ignition and crank the engine in 5 6 second bursts until engine starts 8 Turn the Jump Starter Power Switch back to the OFF position 9 Disconnect the negative engine or chassis ...

Page 6: ...duct will be replaced or repaired at no charge in either of two ways The first which will result in exchanges only is to return the product to the retailer from whom it waspurchased provided that the store is a participating retailer Returns should be made within the time period of the retailer s policy for exchanges usually 30 to 90 days after the sale Proof of purchase may be required Please che...

Page 7: ...mas Medida de conductor estadounidense que que 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 No recomendado 12 NORMAS DE SEGURIDAD DEFINICIONES PELIGRO Indica una situación de peligro inminente que si no se evita provocará la muerte o lesiones graves ADVERTENCIA Indica una situación de peligro potencial que si no se evita podría provocar la muerte o lesiones graves PRECAUCIÓN Indi...

Page 8: ...osivos durante su funcionamiento normal Por esta razón es muy importante que siempre lea este manual antes de utilizar el puente auxiliar de arranque y que siga las instrucciones con exactitud Para reducir el riesgo de explosión de la batería siga estas instrucciones y las publicadas por el fabricante de la batería y el fabricante de cualquier equipo que tenga la intención de utilizar cerca de la ...

Page 9: ...ogresa la recarga los LED rojos se encenderán uno por uno Cargue la unidad hasta el tres rojos y los indicadores verdes de un LED son se encendieron Continúe recargando por una a dos horas después desconecte el adaptador de carga Nota La unidad no se puede cobrar excesivamente usando este método Método de carga de la CC de 12 voltios Para recargar el puente auxiliar de arranque desde una fuente de...

Page 10: ...ipt Picture Warning tirangle 18 1 Inserte el extremo dorado del adaptador de carga de 12 voltios CC en la salida de accesorios de 12 voltios CC del vehículo 2 Inserte el enchufe plateado en el tomacorriente para accesorios de 12 voltios CC del frente de la unidad 3 Cargue la unidad hasta que el indicador verde de COMPLETO FULL se encienda cuando se oprima el botón de nivel de estado de la batería ...

Page 11: ...ués de refrescar abajo período de aproximadamente 10 minutos Cómo inflar neumáticos o productos con vástagos de válvulas 1 Coloque el conector mandril en el vástago de la válvula 2 Asegúrese de que el conector esté metido en el vástago de la válvula tanto como sea posible antes de cerrar el cerrojo de botón 3 Asegúrese de que el cerrojo esté firme 4 Encienda el interruptor de energía del inflador ...

Page 12: ...23 22 JU300CB ManualENSP 072208 qxp 9 26 08 12 47 PM Page 22 ...