Recall Settings
1.
Press the
Recall
button. Notice the button will be illuminated and the cursor on the
display will disappear. This indicates Recall mode. Instrument settings can only be
recalled when the instrument enters this mode.
2.
Use the keypad to enter the memory location you want to recall. Enter a data bank
number between 0 and 9.
3.
Once entered, the saved settings at the location will be immediately recalled.
Note: When in Recall mode, users can recall settings from different locations
without having to press additional keys each time. For example, you can
press 1 to recall settings in location one, and then press 5 to recall settings
in location 5 immediately.
4.
To exit Recall mode, press
Recall
and it will no longer be illuminated. The cursor on
the display will reappear, indicating that the instrument is no longer in Recall mode.
3.4
CONFIG Menu
All setup procedures and settings explained in this section can be accessed from the CONFIG
menu. To access this menu, press (Shift)
and press (Menu)
. Select CONFIG, then
press
Enter
Enter
. The following screen will be shown.
Voltage Limits
The power supply allows users to define the voltage minimum and voltage maximum limits. This
feature will prevent the user from entering a voltage setting outside of these limits. For example,
if Volt-Min is set for 5 V and Volt-Max is set to 15 V, the unit will limit the settable voltage range
to these limit settings.
CONFIG
Volt- Min
Vol t- M ax