background image

 

 

 

 

 

 

 

 

 

Figure 3 - Location of sockets and numbering of contact elements. 

 

Table 2 - Designation of contact elements 

 

No. 

Colour

 

Name of 

contact

 

Type of 

signal

 

Contact element 

assignment

 

Black

 

GND

 

Power 

supply

 

Common wire (ground)

 

Brown

 

DAT low

 

Input

 

Discrete input with active 

"0" (1-20 kHz frequency 

input, pulse counter)

 

Black

 

GND

 

Power 

supply

 

Common wire (ground)

 

White

 

AN in 1

 

Input

 

Analog input No. 1

 

Violet

 

Out 1

 

Output

 

Discrete output No. 1

 

Orange

 

RS-485 A

 

Input/outp

ut

 

Data signal interface RS-

485

 

Black

 

GND

 

Power 

supply

 

Common wire (ground)

 

Red

 

+ V in

 

Power 

supply

 

"+" of on-board power 

supply (rated voltage of 

12 V or 24 V)

 

Blue

 

DAThigh 1

 

Input

 

Discrete input with active 

"1" No. 1

 

10 

Yellow

 

DAThigh 2

 

Input

 

Discrete input with active 

"1" No. 2

 

11 

Grey

 

AN in 2

 

Input

 

Analog input No. 2

 

12 

Pink

 

Out 2

 

Output

 

Discrete output No. 2

 

13 

Green

 

RS-485 B

 

Input/outp

ut

 

Data signal interface RS-

485

 

14 

Black

 

GND

 

Power 

supply

 

Common wire (ground)

 

Summary of Contents for BI 530R TREK

Page 1: ...XIMBANK in c Kyiv MFO 380333 TIN 163033726585 www bitrek com ua sales bitrek com ua 380 44 507 02 07 03061 Ukraine c Kyiv 95 S Otradny ave Telephone 38044 507 02 07 Fax 38044 507 02 02 www bitrek com ua sales bitrek com ua Tracking device for moving objects BI 530R TREK Operating manual Version 2017 03 1 ...

Page 2: ...tions 9 Electrical connections 9 Device to computer connection 9 Description of display bodies 11 Adjustment of BI 530R TREK device 11 Basic information 11 List of information commands to operate the device 11 List of control commands to operate the device 14 Basic configuration 16 Security settings 16 Adjustment of I O elements 17 Notifications 21 Roaming options 21 Configuring the device to work...

Page 3: ... the power socket and inputs outputs turn off the power supply Transportation and storage Transportation of tracking device in the transport packaging of the manufacturer is allowed by all kinds of enclosed land and sea transport rail cars containers vehicles of closed type bilges etc Transportation in pressurized heated compartments of the aircraft is allowed Transportation and storage shall be c...

Page 4: ...me mode the tracking device determines location and movement parameters of the object time geographical coordinates speed and direction collects and processes information from the analog digital and discrete sensors ensures control over actuating mechanisms upon command from the control dispatching panel Received data are recorded and stored in an internal log which is implemented on microchip of ...

Page 5: ... 2 12 Number of discrete outputs 2 13 Type of power supply Direct current 14 Accumulator battery capacity 130 mAh 15 Supply voltage From 6 V to 36 V 16 Average consumption current 12 V 60 mA 17 Range of voltages of discrete inputs From 0 V to 40 V 18 Type of discrete outputs Open collector 19 Maximum current of discrete outputs 0 5 А 20 Number of analog inputs 2 21 Range of voltage of analog input...

Page 6: ...echnical data sheet 1 piece 4 Warranty card 1 piece Preparation for operation commissioning SIM card installation To operate in GSM network device shall contain installed SIM card of Micro SIM format Phone book of SIM card shall remain empty PIN code shall be removed use of SIM card with PIN code can be allowed subject to entering the PIN code to the device settings To install the SIM card disconn...

Page 7: ...e tracking device contains sockets for connecting cables Connecting cables in turn have outlets for power analog digital discrete sensors and actuating mechanisms Location of sockets and numbering of contacts are shown in Figure 3 Marking of connector pins for power supply sensors and peripherals is shown in Table 2 ...

Page 8: ...N in 1 Input Analog input No 1 5 Violet Out 1 Output Discrete output No 1 6 Orange RS 485 A Input outp ut Data signal interface RS 485 7 Black GND Power supply Common wire ground 8 Red V in Power supply of on board power supply rated voltage of 12 V or 24 V 9 Blue DAThigh 1 Input Discrete input with active 1 No 1 10 Yellow DAThigh 2 Input Discrete input with active 1 No 2 11 Grey AN in 2 Input Ana...

Page 9: ... negative of the power ground The passive state for this input is the lack of connection in the air input The active state for the discrete inputs with active 1 is to supply to these inputs the voltage exceeding 8 V The passive state for these inputs is the lack of connection in the air input Analog input voltage can range from 0 V to 27 V The discrete outputs of the device are made according to t...

Page 10: ... official website http www ftdichip com To exchange data with the device use a terminal program Settings of the terminal speed 115200 bit second data bit 8 stop bit 1 no parity check no flow control Figure 4 Connection of the cable of USB UART converter to the device BI 530R TREK Once connected the device will transmit data about its state to the terminal In addition the user is able to use a term...

Page 11: ...o a computer 2 Remotely using SMS commands 3 Remotely using the configuration server Setting of the device through any of the available methods is limited with the setting of the required values of the device parameters Each parameter has its own unique ID Special commands are used to read record the values of selected parameter At remote configuration via SMS take into consideration that the tota...

Page 12: ...server GSM level of GSM signal 1 minimum 5 maximum Roaming SIM card in roaming 0 home network 1 roaming Current GPS coordinates and time of device Command to be send getgps Example of response GPS 1 Sat 7 Lat 50 2345 Long 30 1652 Alt 123 Speed 0 Dir 77 Date 2016 2 15 Time 14 37 32 where GPS status of GPS data 1 valid 0 invalid Sat number of satellites visible for the device Lat latitude last known...

Page 13: ...xxx xxxxx 0 where IMEI xxxxxxxxxxxxxxx identification number IMEI of the device APN gps utel ua access point for GPRS connection to be specified by the operator Login none access login to GPRS to be specified by the operator usually it is not required Password none access password to GPRS to be specified by the operator usually it is not required IP xxx xxx xxx xxx Server IP address for data trans...

Page 14: ...f ignition yes 8 ignitionon Deactivation of the safety locking of ignition yes Notes to Table 4 Reload of device processor Command to be send cpureset No response is returned for this command Receipt of the command initiates a complete restart of all device processes Restoring of original state of profile settings Command to be send rstallprof No response is returned for this command Receipt of th...

Page 15: ...the device via GPRS channel Note Enable download for the SIM card and set the session timeout not less than 10 seconds There are following responses at attempt to update the device software BOOT UPDATE DOWNLOAD OK successful update BOOT WAITE ERROR exceeded timeout at downloading software update BOOT HOST CONNECT ERROR failure to connect to SW server BOOT PAGE LOAD ERROR failure to load the file B...

Page 16: ... grouped in Server and GPRS and Tracking After setting up the necessary parameters the device will transmit data about its current location to the server All parameters available for configuration are specified in Appendix 1 Security settings To meet the safety conditions access to the configuration of the device can be limited At connection your device to the PC using USB UART converter every tim...

Page 17: ... Each sensor is an I O element and has a group consisting of 6 parameters for setting For example to set the value of power supply voltage level to the server use group of parameters of ID 0410 0411 0412 0413 0414 0415 These options have the following structure 0410 0411 0412 0413 0414 0415 First 3 numbers green refer to parameter group number to configure the I O element Last number grey is a par...

Page 18: ... earliest possible opportunity Parameter 2 Upper limit set the upper limit of the I O element Parameter 3 Lower limit set the lower limit of the I O element Parameter 4 Set the type of the generated event 0 Returning to the range At a specific range of sensor values range of values is specified as follows lower limit of the range is recorded to the corresponding parameter Lower limit upper limit o...

Page 19: ...g of the voltage above 10 V will generate the event see Figure 6 Figure 6 Generation of event by leaving the range 2 Returning leaving to of the range Event is generated every time when the actual value of the sensor is out of the limits of the predetermined range Example The lower voltage limit is set to 5 V 5 000 mV the upper limit is set to 10 V 10 000 mV When the actual voltage crosses limits ...

Page 20: ...nge When one of the events is generated the actual value of the sensor starts to be transmitted to the server 7 Change of the input value to a predetermined value Changing of the input value to the predetermined value in either direction will cause the event generation The value is recorded to the parameter Upper limit 8 Monitoring change of the input value to a predetermined value When the event ...

Page 21: ...rigger for outgoing SMS messages In addition to the SMS message you can add customized text where the text length shall not exceed 30 characters in the Latin alphabet Roaming options The tracking device BI 530R TREK is able to operate in two modes in the home network mode and in the operating mode with a predetermined list of authorized operators Operation mode is set with ID 0917 parameter In the...

Page 22: ...Appendix 1 Line with electronic card value shall contain exactly 10 characters numbers 0 9 or uppercase A F Each pair of symbols encodes one byte in ASCII representation The lowest byte of the electronic card is recorded first and so on in ascending order In the pair of characters the first character is the senior the second is the younger half byte Sample of setting At approaching RFID card the d...

Page 23: ...ed values are passed by different I O elements see Appendix 2 In addition if fuel level sensors are equipped with a built in temperature sensor it is possible to obtain these data and transfer them to the server see Appendix 2 ...

Page 24: ...on with the configuration server 0 disabled 1 enabled 1 settingsHost 0220 string IP or DNS of WEB configuration server configurator bitrek com ua settingsPort 0221 2 byte PORT of WEB configuration server 55755 settingsTimeOut 0222 2 byte Period of connection to WEB configuration server second 900 settingsPass 0223 string Access password to WEB configuration server 11111 APN 0242 string Access poin...

Page 25: ... 901 1 byte Permission to record by distance 1 Enable Angle Period 902 1 byte Permission to record by azimuth 1 Day Period 903 2 byte Period of readout by time at ignition on second 30 Night Period 0011 2 byte Period of readout by time at ignition off second 30 Dist Period 0012 2 byte Period of readout by distance m 500 Angle Period 0013 2 byte Period of readout by azimuth degree 10 Send Period 02...

Page 26: ...yte Timeout of movement start according to the accelerometer 0 1 sec 50 Stop Move Timeout 0285 2 byte Timeout of movement stop according to the accelerometer 0 1 sec 200 Min_GPS_Speed 0918 1 byte Minimum GPS speed for motion detection km hour 5 Axel Sleep Enable 0911 1 byte Sleep mode by accelerometer 0 disabled 1 enabled 0 Wait_sleep_ timeout 4007 2 byte Timeout to go to sleep mode by acceleromet...

Page 27: ...telephone number 5 Phone6 0267 string Authorized telephone number 6 Phone7 0268 string Authorized telephone number 7 Phone8 0269 string Authorized telephone number 8 SMS Login 0252 string Access login by SMS SMS Password 0253 string Access password by SMS Device_PIN 0910 string Access password to the device 11111 SIM_PIN 0818 1 byte Installation of PIN code of SIM card operator Name of parameter I...

Page 28: ... reboot 0 complex 1 modem only 0 ErrSatNum 0992 1 byte Authorization to set the number of satellites at the loss of GPS signal pcs 0 ringNum 0912 1 byte Number of rings before automatic response to check the SIM card pcs 3 Notification RingEnable 0913 1 byte Authorization of outgoing voice calls 0 OutCallTrigger 0914 2 byte ID of I O element trigger of an outgoing voice call Name of parameter ID a...

Page 29: ...aracters in the Latin alphabet Roaming Operator selection 0917 1 byte Operator selection mode 0 UsipTable 0020 005 9 string List of codes of authorized operators UsAPNTable 0060 009 9 string List of APN of authorized operators UsLoginTable 0100 013 9 string List of GPRS logins of authorized operators UsPassTable 0140 017 9 string List of GPRS passwords of authorized operators ...

Page 30: ... 0915 1 byte Service authorization RFID reader via RCS SOVA protocol by RS 485 bus at 9 network address and control of digital outputs 10 monitoring without control 13 Out 1 14 Out 2 0 Ekey_num 0920 0939 8 byte ID of allowed RFID cards MinDuration 0349 1 byte Filter of discrete inputs Duration less than the predetermined levels will be filtered 10 msec 5 ...

Page 31: ...No 2 filtering 1 off filtration range is 2 65535 c u 19 ValidFuelLevel 0819 1 byte Permission to use the last valid level of fuel level 0 Polling_period_ fuel 0197 1 byte Polling period for 4 fuel level sensors 100 ms 100 Factor F 0950 4 byte F coefficient for Kalman filter c u 1000000 Factor Q 0951 4 byte Q coefficient for Kalman filter c u 1000000 Factor H 0952 4 byte H coefficient for Kalman fi...

Page 32: ...istration status in the GSM network 13 GPRS net stat 119 0770 0771 0772 0773 0774 0775 Registration status in the GPRS network 14 GPRS content stat 120 0780 0781 0782 0783 0784 0785 Activation status of GPRS content 15 SIM stat 121 0790 0791 0792 0793 0794 0795 Transfer of SIM card status 16 dLow 1 0340 0341 0342 0343 0344 0345 Discrete input with active 0 17 dHigh1 5 0540 0541 0542 0543 0544 0545...

Page 33: ...3 0884 0885 Polling of unfiltered fuel level sensor 6 network address 33 fuelTemp1 102 0600 0601 0602 0603 0604 0605 Fuel temperature per fuel level sensor 1 network address 34 fuelTemp2 103 0610 0611 0612 0613 0614 0615 Fuel temperature per fuel level sensor 2 network address 35 fuelTemp5 127 0520 0521 0522 0523 0524 0525 Fuel temperature per fuel level sensor 5 network address 36 fuelTemp6 128 0...

Page 34: ... 4030 4031 4032 4033 4034 4035 Positioning by base stations 46 iCellID cell_id 4040 4041 4042 4043 4044 4045 Positioning by base stations 47 Rx_level rx_level 4050 4051 4052 4053 4054 4055 Positioning by base stations 48 Socket_stat 177 5020 5021 5022 5023 5024 5025 Status of server connection socket Note Function to determine the location by the base stations is available only when devices operat...

Page 35: ...35 Document version Date Document version Note 1 19 2018 Ver 0 1 Basic document ...