18
4 - moni entering the
range;
5 - moni leaving the range;
6 - moni return to/leaving
the range;
7 - generation of the event to
change the input value to a
predetermined value;
8 - generation of the event to
change the input value to a
predetermined value + monitoring
5
Averaging constant
From 0 and higher
Notes to Table 5:
Parameter 0 - on/off of transmission of I/O element to the server.
Parameter 1 - Priority: low/high. While selecting "Priority:
low" - data of the sensor will be sent to the server with the following data
packet. While selecting "Priority: high" data of the sensor will be sent to
the server at the earliest possible opportunity.
Parameter 2 - Upper limit - set the upper limit of the I/O element.
Parameter 3 - Lower limit - set the lower limit of the I/O element.
Parameter 4 - Set the type of the generated event:
0 - Returning to the range.
At a specific range of sensor values (range of values is specified as
follows - lower limit of the range is recorded to the corresponding
parameter - "Lower limit", upper limit of the range is recorded to the
corresponding parameter "Upper limit"), the event will be generated
when the actual value of the sensor gets within the specified range.
In other cases, the event will not be created and the information will
not be sent to the server.
Example: The lower voltage limit is set to 0, the upper limit is set to
10 V (10 000 mV). Lowering the voltage below 10 V will generate
the event (see Figure 5).