16
Activate/deactivate the safety locking of ignition.
Command to activate safe locking – ignitionon;
Command to deactivate safe locking – ignitionoff;
In case of activation of secure locking the discrete output Out 1 will be
activated if the speed according to GPS is less than 5 km/h.
Examples of response:
«Set RQS To Ignition On» - ignition switch on;
«Set RQS To Ignition Off» - ignition switch off;
Basic configuration
After installing the SIM-card of the mobile operator and connection of the
power supply, the device shall be configured to transmit data to the server.
All adjustable parameters of the device are divided into groups:
Server and GPRS.
Tracking.
Security.
Service.
Voice communication.
Roaming.
Setting required for basic operation of the device include data
transmission and tracking. They are grouped in "Server and GPRS" and
"Tracking". After setting up the necessary parameters the device will
transmit data about its current location to the server.
All parameters available for configuration are specified in
Appendix
1
.
Security settings
To meet the safety conditions, access to the configuration of the
device can be limited.
At connection your device to the PC using USB-UART converter,
every time you send a command, the device requires the access password.
Standard access code is 11111. Lifetime of password is 60 seconds. After
this timeout the password shall be re-entered. Access password can be
changed by the user (ID 0910, see
Appendix 1).
Format of sending a standard password to the device is TPASS:
11111;
Examples of response:
«TASK COM TERM: PASSWORD OK» – correct password is entered;
«TASK COM TERM: INCORRECT PASSWORD» – incorrect password is
entered;
When sending commands via SMS, set the login and password of
SMS access. To set the login use ID 0252 parameter, to set the password
use ID 0253.