Triggering the StreamSync Acquisition Enginer
The Cyton-CXP
CYT-2-6
BitFlow, Inc.
Version A.0
2.3 Triggering the StreamSync Acquisition Enginer
One of the areas where the power of the Acquisition Engine is really seen is with
regards to triggering. There are many more ways to use triggers in the Acquisition
Engine. Primarily triggers can be used to “open” a window and/or to “close” a win-
dow. For example, a trigger could be used to start the acquisition of each frame and/
or end the acquisition of each frame.
Further, a trigger could be use to start the acquisition of each volume (sequence of
frames) and/or end the acquisition of a volume. Further flexibility comes from the fact
that the source for each event (i.e. open or close) can be different or the same. This
means a frame could started with one trigger or ended with another, or the frame
could start on the rising edge and end on the falling edge of the same trigger. Please
refer to Figure 2-2 for more information on where a trigger can be used to change the
state of the Acquisition Engine.