CXP Subsystem Registers
CON104
Version A.0
BitFlow, Inc.
CYT-8-3
0_POCXP_EN_
POWER
RO, CON104[0], Karbon-CXP, Cyton-CXP
CXP Power enabled.
0_POCXP_EN_
24V_REG
RO, CON104[1], Karbon-CXP, Cyton-CXP
24V Regulator enabled.
0_POCXP_EN_
CAM_SENSE
RO, CON104[2], Karbon-CXP, Cyton-CXP
Enable POCXP Sense.
0_POCXP_CAM_
IS_POCXP
RO, CON104[3], Karbon-CXP, Cyton-CXP
Reserved for future use.
0_POCXP_
SHORT_
DETECTED
RO, CON104[4], Karbon-CXP, Cyton-CXP
Only valid if POCXP_EN_CAM_SENSE is asserted. This status bit tells if an short circuit
was detected from the camera in response to POCXP_EN_CAM_SENSE.
0_POCXP_
OPEN_
DETECTED
RO, CON104[5], Karbon-CXP, Cyton-CXP
Only valid if POCXP_EN_CAM_SENSE is asserted. This status bit tells if an open circuit
was detected from the camera in response to POCXP_EN_CAM_SENSE. It likely
means there is no camera detected.
0_POCXP_
OVER_
DETECTED
RO, CON104[6], Karbon-CXP, Cyton-CXP
This status bit indicated over current detected. The protection circuit will immediately
disable POCXP_EN_POWER and POCXP_EN_24V_REG in this event. The error is also
latched in POCXP_OVER_LATCH.
0_POCXP_
OVER_LATCH
RO, CON104[7], Karbon-CXP, Cyton-CXP
Latched version of POCXP_OVER_DETECTED. Cleared by hardware when both
POCXP_EN_POWER and POCXP_EN_24_REG transition from 0 to 1.
Summary of Contents for Cyton-CXP
Page 150: ...CON64 The Cyton CXP CYT 7 20 BitFlow Inc Version A 0 ...
Page 346: ...CON428 The Cyton CXP CYT 8 196 BitFlow Inc Version A 0 ...
Page 360: ...Camera Link Controls CCs The Cyton CXP CYT 9 14 BitFlow Inc Version A 0 ...
Page 372: ...I O Connector Pinout for the Cyton CXP The Cyton CXP CYT 10 12 BitFlow Inc Version A 0 ...
Page 382: ...Index BitFlow Inc ...
Page 383: ...Index BitFlow Inc ...
Page 384: ...Index BitFlow Inc ...
Page 385: ...Index BitFlow Inc ...
Page 386: ...Index BitFlow Inc ...
Page 387: ...Index BitFlow Inc ...
Page 388: ...Index BitFlow Inc ...