background image

9

Laser Illuminator

Adaptive IR Laser Illuminator

The A300 camera uses adaptive IR laser illuminator to provide 

up to 1000 ft /1500 ft of long range illumination. IR laser uses 

diffused illumination that provide the long distance visibility.

Precaution & Specs:

1.  This product uses Class 3B laser light product.

2.  Supports Manual / Auto IR laser control

3.  Uses synchronous zoom with continuously adjustable il-

lumination angle of 68 ° ~ 2 °.

4.  Supports intelligent light-adjustment which automati-

cally adjust the power of infrared laser light and avoids 

reflective object and close range image overexposure.

5.  Mount a laser dome camera at a height of six (6) meters 

(19.7 ft) from the ground. To avoid bodily injury from the 

laser radiation, please make sure that no one is within the 

range of three (3) meters (9 ft) from the camera when the 

laser is working.

6.  When the IR laser is operating, do not look directly into 

the laser beam or obstruct the pathway of the beam.

7.  Everyone who uses a laser should be aware of the risks 

and take necessary caution when handling, operating 

and maintaining the product.

Wall Mount

1.  Open the bracket cover, mount it onto the wall or pole 

(use pole adaptor).

2.  Put on 3 screws onto the bottom of the camera, leave 

enough space to fit in the screw holes on the bracket, 

not to screw tight.

3.  Hold up the camera close under the bracket, insert the 

tail-cable of the camera into the chest of the bracket.

4.  Insert the 3 screws into the screw holes and turn the 

camera counterclock wise so that the camera can be held 

by the camera. Screw up the 3 screws but not too tight.

5.  Put on the 4th screw and screw in tightly. Screw in the 

rest of the screws tightly.

6.  Finish the cable connection. Put all cable and connectors 

inside of the bracket.

7.  Put the cover back to the bracket and screw in securely.

Summary of Contents for NDI EYES A300

Page 1: ...USER MANUAL PART 1 FULL NDI NO COMPROMISES EYES A300...

Page 2: ...g the Camera 8 Wall Mount 9 Laser Illuminator 9 Use SDI video output 10 Starting the Camera 10 Setup Camera ID Baud Rate and Control Protocol 10 Controlling the Camera 11 Adjusting and Setting with Me...

Page 3: ...her trademarks company names and product names contained in this manual are the property of their respective owners IMPORTANT INFORMATION Legal Notice Attention To ensure account security please chang...

Page 4: ...erein may result in hazardous laser emissions Maintenance Precautions If there is dust on the front glass surface remove the dust gently using an oil free brush or a rubber dust blowing ball If there...

Page 5: ...rs IR ON OFF is available Outdoor Environmental Rating IP67 Corrosion Resistant Treatment Various Image Functionalities WDR BLC Defog Day Night Supports 120 tilt 360 pan range adaptive speed up to 150...

Page 6: ...arm Inputs x2 Data Cable Alarm Output x1 SDI Signal CAMERA SIDE CONTROL SIDE 1 IR Laser illuminator 2 Lens 3 Nitrogen Filled Housing Valves NOTE Nitrogen filled Valves for factory use only Do not open...

Page 7: ...and the clamp of the cable connector is intact SDI Signal Cable In order to ensure the quality of the installation of the project the HD SDI and 3G SDI signals have a high data transmission rate of di...

Page 8: ...d the pendant mount bracket may be necessary during mounting For their model refer to the accessory list recommended by your dealer The wall bearing capacity and the bracket length must meet all onsit...

Page 9: ...m the camera when the laser is working 6 When the IR laser is operating do not look directly into the laser beam or obstruct the pathway of the beam 7 Everyone who uses a laser should be aware of the...

Page 10: ...ction TX TX RX RS 485 A RS 485 RS 485 D RX RS 485 B RS 485 RS 485 D 1 2 RS422 VISCA control connection diagram SONY Keyboard RS422 Connection VISCA None Sony Keyboard RS422 Connection Setup Camera ID...

Page 11: ...match the control system or keyboard camera ID and Baud Rate setting to the cameras PTZ Control 1 8 9600 None None 1 PELCO D Port Mode Stop Bits Data Bits Baud Rate Flow Control Parity Address Code PT...

Page 12: ...ake the subject appear clearer This is set to ON OFF WIDE D Wide dynamic range mode ON OFF The cam era distinguishes light and dark areas within the same scene adjusts the brightness for dark areas an...

Page 13: ...form manual A F RECOVER TIME When the camera is not in operation if in the manual focus mode after the A F RECOVER TIME it will automatically transfer to the automatic focus If the time is 0 then the...

Page 14: ...erwise the camera and keyboard and IP control will be unable to communicate FLIP Select ON to flip the image if you need to lift the camera VIDEO FORMAT SDI IP True Dual Output You can have parallel S...

Page 15: ...resets still store camera positions and image parameters but 17 128 presets will only store camera positions You can set the presets to number 17 128 if you don t want the preset to memorize the image...

Page 16: ...e camera scan 1 Push the joystick to the right to enter this setting menu PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET...

Page 17: ...17 Dimensions Unit mm 423 183 118 8 118 8 4 5 16 18 UNC 20...

Page 18: ...18...

Page 19: ...19...

Page 20: ...WELCOME TO THE FUTURE bird dog tv hello bi rd dog tv...

Reviews: