Use SDI video output

Starting the Camera

After you have mounted the camera properly, connect the 

camera to power.

Each time the camera is powered on, it will perform a self-

test to check the Pan/Tilt/Zoom (PTZ function). After self-

test, you can operate the camera.

NOTE!

•  The self-test process starts after the camera is pow-

ered up. Please wait patiently.

•  When the operating temperature is lower than zero 

degrees Celsius, the camera will be automatically pre-

heat (the pre-heat process takes 30 minutes at most). 

The  self-test  starts  only  after  the  temperature  rises 

above zero degrees Celsius.

Connect Camera to Monitor/SDI Device

To view your camera, you need to use the coaxial cable to 

connect your camera to monitor or SDI device.

* The monitor/device must support the signal of HD-SDI or 

3G-SDI.

Connect Camera with Controller

To control and configure your camera, you need to connect 

with control system (or control keyboard) for communication 

by RS-485/RS422. Set up the protocol of communication by 

control keyboard, the camera can auto detect VISCA and 

PELCO-D.

1. Connection

1.1 RS485 (PELCO D) control connection diagram

Connect the Camera’s RS485+ and RS485 to RS485/TX+ and 

RS485/TX- on the control system/keyboard. The identity of 

the control system or equipment may be different; the corre-

sponding relationship is as follows:

Camera

(RS485)

1. RX +

2. RX –

Keyboard

(PELCO P/D)

6. TX+

7. TX –

RS485 (PELCO D)

Multiple Cameras Connection

RX +

RX –

RX +

RX –

RX +

RX –

RX +

RX –

CAM1

SYSTEM / 

KEYBOARD

(PELCO D)

CAM 2

CAM 3

CAM 255

RS485 PELCO D

System / Keyboard

Connection

TX –

TX +

RX +

RS 485 A

RS 485 +

RS 485 D+

RX –

RS 485 B

RS 485 –

RS 485 D–

1.2 RS422 (VISCA) control connection diagram

•  SONY Keyboard RS422 Connection

•  VISCA (None-Sony) Keyboard RS422 Connection

Setup Camera ID, Baud Rate and 
Control Protocol

In order for you to control a camera, the camera ID, baud rate 

and control protocol have to be set up in advance, Baud rate 

and the camera ID setting on the camera have to be the same 

as baud rate and camera ID setting on the system/control 

keyboard. The camera can auto detect the VISCA and PEL-

CO-D, only need to set up the camera address and baud rate.

Connect the camera to a monitor. There is an initial setting 

page displaying on the screen for 5 seconds when the cam-

era is powered on. On the page, it shows the factory default 

setting of the camera ID, baud rate and other information. 

Suggest taking a picture of this default setting information 

for setting keyboard use. Set the keyboard or control system 

to match the camera ID, baud rate setting with the camera.

1.  Camera supports VISCA and PELCO-D protocols, proto-

col is detected automatically by the camera.

2.  Factory Default Setting: For both SDI and IP video, Baud 

Rate: 9600, Camera ID: 001, Pelco Protocol.

Camera

(RS422)

4. TX +

3. TX –

2. RX +

1. RX –

Keyboard

1.  --- 

2.  ---

3.  ---

4.  ---

5. GND

6. RXD IN –

7. RXD IN +

8. TXD IN –

9. TXD IN +

RS422 (VISCA)

Multiple Cameras Connection

(SONY Keyboard)

RX +

RX –

TX +

TX –

GND

RX +

RX –T

X +

TX –

GND

RX +

RX –T

X +

TX –

GND

RX +

RX –T

X +

TX –

GND

KEYBOARD

CAM 1

CAM 2

CAM 7

SONY Keyboard

RS422 Connection

Camera

(RS422)

4. TX +

3. TX –

2. RX +

1. RX –

Keyboard

1. GND

2. RXD IN –

3. RXD IN +

4. TXD IN –

5. TXD IN +

RS422 (VISCA)

Multiple Cameras Connection

(VISCA Keyboard)

RX +

RX –T

X +

TX –

GND

RX +

RX –T

X +

TX –

GND

RX +

RX –T

X +

TX –

GND

RX +

RX –T

X +

TX –

GND

KEYBOARD

CAM 1

CAM 2

CAM 7

VISCA Keyboard

Connection

Summary of Contents for NDI EYES A300

Page 1: ...USER MANUAL PART 1 FULL NDI NO COMPROMISES EYES A300...

Page 2: ...g the Camera 8 Wall Mount 9 Laser Illuminator 9 Use SDI video output 10 Starting the Camera 10 Setup Camera ID Baud Rate and Control Protocol 10 Controlling the Camera 11 Adjusting and Setting with Me...

Page 3: ...her trademarks company names and product names contained in this manual are the property of their respective owners IMPORTANT INFORMATION Legal Notice Attention To ensure account security please chang...

Page 4: ...erein may result in hazardous laser emissions Maintenance Precautions If there is dust on the front glass surface remove the dust gently using an oil free brush or a rubber dust blowing ball If there...

Page 5: ...rs IR ON OFF is available Outdoor Environmental Rating IP67 Corrosion Resistant Treatment Various Image Functionalities WDR BLC Defog Day Night Supports 120 tilt 360 pan range adaptive speed up to 150...

Page 6: ...arm Inputs x2 Data Cable Alarm Output x1 SDI Signal CAMERA SIDE CONTROL SIDE 1 IR Laser illuminator 2 Lens 3 Nitrogen Filled Housing Valves NOTE Nitrogen filled Valves for factory use only Do not open...

Page 7: ...and the clamp of the cable connector is intact SDI Signal Cable In order to ensure the quality of the installation of the project the HD SDI and 3G SDI signals have a high data transmission rate of di...

Page 8: ...d the pendant mount bracket may be necessary during mounting For their model refer to the accessory list recommended by your dealer The wall bearing capacity and the bracket length must meet all onsit...

Page 9: ...m the camera when the laser is working 6 When the IR laser is operating do not look directly into the laser beam or obstruct the pathway of the beam 7 Everyone who uses a laser should be aware of the...

Page 10: ...ction TX TX RX RS 485 A RS 485 RS 485 D RX RS 485 B RS 485 RS 485 D 1 2 RS422 VISCA control connection diagram SONY Keyboard RS422 Connection VISCA None Sony Keyboard RS422 Connection Setup Camera ID...

Page 11: ...match the control system or keyboard camera ID and Baud Rate setting to the cameras PTZ Control 1 8 9600 None None 1 PELCO D Port Mode Stop Bits Data Bits Baud Rate Flow Control Parity Address Code PT...

Page 12: ...ake the subject appear clearer This is set to ON OFF WIDE D Wide dynamic range mode ON OFF The cam era distinguishes light and dark areas within the same scene adjusts the brightness for dark areas an...

Page 13: ...form manual A F RECOVER TIME When the camera is not in operation if in the manual focus mode after the A F RECOVER TIME it will automatically transfer to the automatic focus If the time is 0 then the...

Page 14: ...erwise the camera and keyboard and IP control will be unable to communicate FLIP Select ON to flip the image if you need to lift the camera VIDEO FORMAT SDI IP True Dual Output You can have parallel S...

Page 15: ...resets still store camera positions and image parameters but 17 128 presets will only store camera positions You can set the presets to number 17 128 if you don t want the preset to memorize the image...

Page 16: ...e camera scan 1 Push the joystick to the right to enter this setting menu PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET NUMBER 000 000 000 000 DEFAULT DWELL 000 000 000 000 PRESET...

Page 17: ...17 Dimensions Unit mm 423 183 118 8 118 8 4 5 16 18 UNC 20...

Page 18: ...18...

Page 19: ...19...

Page 20: ...WELCOME TO THE FUTURE bird dog tv hello bi rd dog tv...

Reviews: