PC/Rack Mount SignalHawk with ASL
156
Markers
6 Markers; Modes: On/Off, Standard, Marker
to Max Peak, Marker to Next Peak, Marker
Freq to Center, Marker Ampt to Ref Level,
Marker Delta, Marker Type Line/Icon, Marker
Noise, All Marker to Peaks, All Markers Off.
Also, Marker to Max/Min Peak
User Interface
Reference the user manual and design
specification for further details.
Warm-Up
Specifications apply after a 30 minute warm-
up period at ambient temperature.
General Specifications
Model
Name: Rack-Mount Signal Hawk
Model: SH-36S-RM
Description: Rack-Mount Spectrum Analyzer
Housing
Sheet metal
Power Switch
Momentary push-button
Power Indicator
Green LED
Connectors
N(F) for RF input
Rear USB 2.0 Type B
BNC(F) for external trigger
RJ-45 for Ethernet
Terminal strip for DC input
One front & one rear RJ-45 for pass-through
Ethernet connection
Additional Peripheral
Connectors
2.5mm Audio out (rear)
VGA and DVI Video out (rear)
USB ports (rear)
DB 25 parallel port (rear)
Host Status Indicator
Multi-Colored LED's for individual host device
power present
RF Input Impedance
50 ohms, nominal
RF Input VSWR
1.8:1 typ, 2.0:1 max (internal attenuator = 10dB
or greater)
Max DC input
± 50 V
Max RF input
+20 dBm; damage level is +30dBm for 30
sec.
Power Input
120/240 VAC, IEC inlet
12 & 24/48 VDC, detachable screw terminal
strip
Voltage Range and Power
Requirements
9-60 VDC, 75W peak
84-264 VAC, 75W peak
AC Fuse Options
Dual fuse line/neutral or single line fuse/
neutral shorting bar (neutral un-fused)
Summary of Contents for SignalHawk SH-36S-RM-ASL
Page 37: ...Installation 23 Rack Mount SignalHawk Connection Diagram...
Page 126: ...PC Rack Mount SignalHawk with ASL 112 Channel Power Measurement...
Page 130: ...PC Rack Mount SignalHawk with ASL 116 Time Domain Measurement...
Page 132: ...PC Rack Mount SignalHawk with ASL 118 Field Strength Measurement...
Page 135: ...Measurements 121 Demodulate Signal Measurement...
Page 137: ...Measurements 123 Carrier to Interference Ratio Carrier On...
Page 138: ...PC Rack Mount SignalHawk with ASL 124 Carrier to Interference Ratio Carrier Off...