11
2.1
Mechanical Mounting
Mounting the bracket
clamping side
Mounting the bracket
with compression spring
Mounting the bracket
with coil INT-FIX 50
2
Installation
Fig. 2
Fig. 3
Fig. 4
Fig. 5
The instructions presented here are a recommendation only. The arrangement of the individual com-
ponents depends on the particular gate design and the conditions in the building.
INT-MOB 50
recessed
INT-MOB 50
surface-mounted
2
2
2
6
9
12
13
14
15
16
11
9
12
8
4
6
2
10
5
2
15
10
15
16
13
17
17
1
7
9
9
4
1.
Align both mounting brackets
horizontally
and attach them. Tighten only the bolts
on the
spring side. Do not tighten the bolts
on the ten-
sioning side yet.
2.
Mount the converter INT-MOB 50
on the
clamping side (recommendation) cable glands
downward. Alternatively it can also be installed
recessed as shown below. In this type of mount-
ing, the loose end of the cable
is passed
through the converter INT-MOB 50
and con-
nected to the gate.
3.
Mount the coil INT-FIX 50
to the floor bracket
at the cable height. Do not tighten the bolts
yet.
4.
Pull the cable
through the hollow pin
with spring
, plastic sleeve
and mounting
bracket
. Leave 0.5 m of cable projecting for
contacting the gate.Then pull the cable
through
coil INT-FIX 50
, converter INT-MOB 50
, on
the clamping side through mounting bracket
,
plastic sleeve
, washer
and banjo bolt
with
two screwed-on nuts
and leave approx. 0.5 m
projecting. Screw on the first hexagon nut
up to
the heaxd of the banjo bolt.
5.
Fix the cable on the spring side using bolt
. On
the clamping side, tension the cable firmly by hand so
the spring
is preloaded and secure with bolt
.
6.
Cut the cable on the left and right to the required
length and press on a cable lug
on both sides.
Screw the cable lugs
onto the gate using hexa-
gon bolts
and washer
. Take particular care
that the contact points on the gate make a good
connection. Clean the contact point and scrape
off any paint or contamination.
7.
Align the coil INT-FIX 50
vertically and hori-
zontally so that the cable passes through the mid-
dle of the passage tube in the coil. Use shims
underneath the floor bracket
for horizontal
alignment. Tighten the bolts.
8.
Clamp the cable with the first hexagon nut
on the banjo bolt
so it is firmly tightened and
does not sag at any point. Lock with the second
nut.
9.
Mount the safety edges on the moving gate
section and route the cable to the converter
INT-MOB 50
.
10.
Mount the safety edges on the fixed gate sec-
tion and route the cable to the switching device.