●Is the life span of the filter overdue?
(Need to check the filter usage status number)
=> Replace the filter.
●Is the filter wrongly fixed?
=> Fix it right.
●Is the water supply suspended?
=> Wait until the water supply is resumed.
●Is the hose bent or crushed?
=> Set it right.
Symptoms
Causes and actions
Water keeps [dripping] from the outlets (Especially the
acidic water outlet) even after the water supply control
valve is turned off.
When tested with the pH test solution, it is yellow for the
acidic water, but in case of the alkaline water, the color
becomes neutral momentarily.
Water smells disinfectants
* Various causes can lead to the symptom. If the problem
is not solved by replacing the filter, the water purification
process needs to be selected to check the problem.
When there is still nothing found about the problem, the
items on the right side need to be checked.
The power is not turned off when the water supply control
valve is turned off.
Water leakage at the water purifier. (Filter socket)
●The remaining water inside the outset can comes out
=> Not malfunctioning.
●The rinsing operation is in progress.
=> Not malfunctioning.
●It is due to the effect of the carbonic acid in the water.
(Severe in case of the ground water)
=> Use the water after adjusting the stage of the alkaline
ionized water to level 5.
Considering that the alkaline reaction and the acidic
reaction occur in an opposite way, so it is understood that
the alkaline ionized water is generated also if there is acidic
reaction taking place.
We can simply say that the symptom is the result of the
vaporization of the test solution due to the chemical reaction
involving the carbonic acid in the water.
●Check whether the storage container is cleaned.
=> Wash the storage container cleanly.
●The life span of the filter can be shortened due to
pollution depending on the condition of the water supply.
=> Replace the filter (Refer to Page 18~20).
●The ionized water has less crusts of water, meaning that
the water is highly active for reaction. Extremely low
volume of impurities, when spread throughout the water,
can cause the water to be activated together and, possibly,
the water to smell.
=> Use the water by adjusting the alkaline level by down by
1~2 level.
●Check whether the acidic water hose is higher than the
main body.
=> Install the hose 50~70cm below the level of the main
body.
●The system is malfunctioning.
=> After disconnecting the electric cord, you need to
contact the sales shop or the main office for requesting
the repair work.
●Check whether the filter is appropriately fastened into the
filter socket.
=> After checking the filter packing, you need to fasten it to
the filter base appropriately.
29
BTM-303D (영).indd 29