SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS - READ

ALWAYS ADD THE ACID TO WATER ALREADY IN THE DRUM. NEVER ADD WATER TO ACID.

PLEASE FOLLOW THESE IMPORTANT ACID SAFETY INSTRUCTIONS.

ACID SAFETY (WHEN USING BIODOSER TO DOSE ACID)

3. 

WARNING 

-  Do  not  allow  children  to  use  this 

product unless they are closely supervised at all 
times. This is to prevent accidental injury.

3.  Turn  off  the  power  to  the  BioDoser  before 

replacing  the  peristaltic  dosing  pump  squeeze 
tube.

2.  Damage due to using undiluted or insufficiently 

diluted acid is not covered by warranty. 

It  is  important  to  follow  basic  safety  precautions 
when installing and using this electrical equipment, 
including the following :

IMPORTANT :

2. 

WARNING

 - Always read and follow directions 

and  warning  labels  on  containers  of  any 
supplements that you will dose with BioDoser.

4.  Keep all cables and tubes visible and do not bury 

them. Also, position them so that they do not get 
damaged by lawn mowers, hedge trimmers, etc.

CAUTION

 :

1.  Ensure you read and follow all instructions.

1.  The BioDoser must be installed and operated as 

specified.

Your warranty could become invalid should you fail 
to observe the following :

3. 

WARNING

 - ALWAYS USE DILUTED ACID AT A 

RATIO OF NOT LESS THAN 4 PARTS WATER TO 
1 PART ACID.

4.  The life of the unit will be extended (as with most 

other pool equipment) if it is placed indoors or in 
an enclosed structure. This is recommended as 
sunlight can damage the Liquid Crystal Display on 
the face of the control unit. The LCD is covered 
within the warranty on a pro-rata basis.

5. 

WARNING 

-  To  prevent  electrical  shock,  acid 

spillage  or  incorrect  dosing,  replace  damaged 
cords or tubes immediately.

5.  Always  power  the  BioDoser  from  a  genuine 

Bionizer  power  adaptor  or  cable.  An  incorrect 
adaptor could damage the BioDoser and will void 
your warranty.

1. 

WARNING 

- always use diluted acid at 1 part acid 

to 4 or more parts water with BioDoser.

2. 

ALWAYS 

add acid to a larger volume of water. 

NEVER 

add water to acid.

3. 

ALWAYS 

wear safety glasses and gloves.

4. 

ALWAYS 

dilute  acid  in  a  well  ventilated  area, 

preferably outdoors.

5. 

ALWAYS 

have  a  source  of  fresh  water  nearby, 

such as a hose, so you can wash down accidental 
spillages.

6. 

ALWAYS

  ensure  that  the  acid  drum  is  BELOW 

the level of the BioDoser Tee, to ensure that the 
acid cannot syphon from the drum to the pool.

7.  In case of acid spillage onto clothing, eyes, skin, 

concrete etc, wash down with large amounts of 
fresh  water  immediately.  SEEK  MEDICAL 
ADVICE IF NECESSARY.

1. e.g. Add water to a
    20 Litre acid drum
    to approx 1/2 full.

In case of a larger
drum, add 1 part 
acid to 4 parts 
water to be mixed 
as above

2. Add 4 Litres only of
    Hydrochloric Acid.

3. Top off the drum
     with more water.

1. 

WARNING 

- always use diluted acid at 1 part acid 

to 4 or more parts water with BioDoser.

2. 

ALWAYS 

add acid to a larger volume of water. 

NEVER 

add water to acid.

3. 

ALWAYS 

wear safety glasses and gloves.

4. 

ALWAYS 

dilute  acid  in  a  well  ventilated  area, 

preferably outdoors.

5. 

ALWAYS 

have  a  source  of  fresh  water  nearby, 

such as a hose, so you can wash down accidental 
spillages.

6. 

ALWAYS

  ensure  that  the  acid  drum  is  BELOW 

the level of the BioDoser Tee, to ensure that the 
acid cannot syphon from the drum to the pool.

7.  In case of acid spillage onto clothing, eyes, skin, 

concrete etc, wash down with large amounts of 
fresh  water  immediately.  SEEK  MEDICAL 
ADVICE IF NECESSARY.

For pools of 25,000L (6,500 Ga) and under, dilute 8 
parts water to 1 part acid. So add 2 Litres of acid 
for the 20 Litre drum in the example above.

Summary of Contents for BioDoser

Page 1: ...se read before you call us for advice Version 2 1a 19 Sep 2019 www bionizer com au www bionizer com BioDoser C h l o r i n e F r e e F r e s h w a t e r P o o l s DOWN UP AUTO OFF CANCEL PROGRAM SET C...

Page 2: ...ODOSER ILLUSTRATION 4 BIODOSER INSTALLATION 6 CONTROL BOX INSTALLATION 7 DOSING PUMP HOSE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 8 SAFETY INSTRUCTIONS 5 PROGRAMMING YOUR BIODOSER 9 SET DOSE SIZE 9...

Page 3: ...but helps with your overall pool balance by maintaining a steady level of the required supplement rather than adding a largequantityeverysooften Someexampleapplicationsinclude Bionizer is committed t...

Page 4: ...t for 24 hours For example use this function if some bufferwasaddedtothepool Presstoselect Presstosavechangeswhenadjustingsettings Presstoscrollthroughthefourusersettingmenus Add BioDoser dosing pump...

Page 5: ...esimmediately 5 Always power the BioDoser from a genuine Bionizer power adaptor or cable An incorrect adaptorcoulddamagetheBioDoserandwillvoid yourwarranty 1 WARNING alwaysusedilutedacidat1partacid to...

Page 6: ...netoothsaw 4 The Injection Tee must be fitted on the pipe that sends water back to the pool after it has been filtered the ReturnLine The Injection Tee should be installed LAST in the return line afte...

Page 7: ...COMPLETED The control box MUST be mounted vertically with the cables at the bottom in order to be weather resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty CO...

Page 8: ...n the same way as described in the Tee Piece Hose Installationsectionaboveandillustrationbelow AFTER ALL HOSE FITTINGS ARE COMPLETED TEST THE SYSTEM WITH FRESH WATER USING THE MANUAL DOSE FUNCTION PAG...

Page 9: ...ed Presstoalternativelyselect AUTO DELAY and OFF SET DOSE SIZE to enter 5 Minutes to 14 Use the and keys Days DOSING ON OFF KEY Alternatively press DOSING ON OFF to cancel withoutsaving Press PROGRAM...

Page 10: ...ff the pump cover Remove the Squeeze tube The rotor may come out but can be pushedbackinplace Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside LubricatingtheSqueezeTu...

Page 11: ...ube inside pump is not leaking Replace squeeze tube and orrollersasneeded seepage10 WARNING If any supplement has leaked out of hoses wash down the area with fresh water immediately Take the lid off t...

Page 12: ...Suite 410 Toll Free 1 855 8 IONIZE Phone 1 480 696 2387 Scottsdale AZ 85254 Web bionizer com 16427 N Scottsdale Rd USA Email relax bionizer com Bionizer Ltd Maroochydore Bioniser Pty Ltd 1 173 Bradman...

Reviews: