AUTO
:
Unit will dose
supplement according
to the program.
!
Press
PROGRAM / SET
to save the new setting.
This sets the volume to be dosed, each time the
BioDoser is scheduled to add supplement.
The BioDoser has a time clock with battery backup.
When a Dosing Schedule of every 1 to 14 days is
selected, the BioDoser will deliver the dose at the
same time of day as when this schedule is first set.
DELAY
: This function
w i l l sto p t h e u n i t
d o s i n g a n y
supplement for 24
Hours (for example,
choose this function
when buffer is added
to the pool).
The
DOSING ON / OFF
key is also the “Cancel” key to
exit without saving changes in programming screens.
Note for when pumping diluted acid:
Please note that the litres are the total litres of liquid
being pumped, and does not take into account the
dilution ratio of the acid. Take care when using this
function, that you do not overdose the pool with
acid.
This setting will move
between 50mL and
5000mL
MANUAL DOSE
!
Use the and keys to enter setting 50 to 5000
Ç
È
millilitres.
O F F
: Unit will not
dose any supplement
again until this setting
is changed.
Press to alternatively select AUTO, DELAY and OFF :
SET DOSE SIZE
!
to enter 5 Minutes to 14
Use the
Ç
and
È
keys
Days.
DOSING ON / OFF KEY
Alternatively, press
DOSING ON / OFF
to cancel
without saving.
!
Press
PROGRAM / SET
to start pumping.
This will change from 5
Minutes to 14 Days.
This will change from 0
to 5 Litres.
SET DOSING SCHEDULE
!
Use
to enter 0.05 to 5 Litres.
the
Ç
and
È
keys
Remember that 1 Litre equals 200 mL of acid when
the acid is diluted 1 part acid to 4 parts water.
!
Press
PROGRAM / SET
to save the new setting.
This sets the dosing schedule for the dose size.
For example, dose once per hour, or once per
day, or once per 7 days etc. The BioDoser will
only dose when the filtration pump running.
Alternatively, press
DOSING ON / OFF
to cancel
without saving.
Use this function to add a measured dose of
supplement.
PROGRAMMING YOUR BIODOSER
!
If no key has been pressed for 30 seconds, the unit will return to the normal readout display. Any changes
will not be saved.
!
Use the
Ç
and
È
keys to change settings.
PROGRAMMING YOUR BIODOSER
!
When changing a setting, press
PROGRAM / SET
after the desired setting is programmed to save the
changes and return to the normal readout display.
!
To quit any screen without saving changes, press
DOSING ON / OFF
to cancel.
!
Press the
PROGRAM / SET
button to move through each of the four user settings.
9