Removing the Squeeze Tube

At this time, the peristaltic pump squeeze tube either 
needs  to  be  lubricated  or  replaced  as  per  the 
instructions below. 

The  BioDoser  monitors  the  running  time  of  the 
dosing pump and will display a reminder to replace 
the squeeze tube when this time exceeds 50 hours.

PUMP SQUEEZE TUBE LUBRICATION AND 

 

 

 

REPLACEMENT

!

  Switch off the BioDoser and ensure that the pool 

pump is also off. 

!

  Remove  and  inspect  the  squeeze  tube.  If  it  is 

round  and  not  flattened,  and  shows  no  visible 
signs of wear, then it can simply be lubricated as 
per the instructions in this section. 

If the squeeze tube appears a little flattened and 
has wear marks, then it is best to replace it. A new 
squeeze tube can be ordered  at bionizer.com.au.

Damage  caused  by  acid  leaking  from  a  broken 
squeeze tube is not covered by the warranty, so it 
is  your  responsibility  to  check  and  replace  it  as 
necessary.

DOSING PUMP MAINTENANCE

DOSING PUMP MAINTENANCE

10

P u l l   o ff   t h e   p u m p 
cover.

Remove  the  Squeeze 
tube.  The  rotor  may 
come  out,  but  can  be 
pushed back in place.

H o l d   t h e   t o p   a n d 
bottom  of  the  pump 
cover.

Lift up the pump cover 
from the bottom side.

Lubricating the Squeeze Tube

Refitting the Squeeze Tube

(Skip this step when replacing squeeze tube, as these 
are supplied pre-lubricated.)

Apply    a 

THIN  SMEAR 

of  Silicon  grease  to  the 

squeeze tube and pump rotor shaft as shown above.

DO NOT 

over-lubricate, as this will attract dirt and 

grit, which will cause premature wear of the squeeze 
tube and rollers.

WARNING : Use only silicon grease. Petroleum gel 
and  other  oil-based  lubricants  may  cause  the 
squeeze tube to break down, resulting in leakage.

Pull  out  the  pump  rotor  a  little,  and  place  the 
squeeze tube between the pump body and the two 
rollers. 

Push the squeeze tube and rotor into the pump body. 
Ensure  that  the  inlet  and  outlet  are  seated  in  the 
guides on each side of the pump body.

Refitting the Pump Cover

Re-fit the pump cover until it clips into place. There 
should  be  no  gaps  anywhere  between  the  pump 
body and cover. Ensure that the squeeze tube is not 
pinched on either side, after the cover is replaced.

Apply Silicon

grease here.

Summary of Contents for BioDoser

Page 1: ...se read before you call us for advice Version 2 1a 19 Sep 2019 www bionizer com au www bionizer com BioDoser C h l o r i n e F r e e F r e s h w a t e r P o o l s DOWN UP AUTO OFF CANCEL PROGRAM SET C...

Page 2: ...ODOSER ILLUSTRATION 4 BIODOSER INSTALLATION 6 CONTROL BOX INSTALLATION 7 DOSING PUMP HOSE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 8 SAFETY INSTRUCTIONS 5 PROGRAMMING YOUR BIODOSER 9 SET DOSE SIZE 9...

Page 3: ...but helps with your overall pool balance by maintaining a steady level of the required supplement rather than adding a largequantityeverysooften Someexampleapplicationsinclude Bionizer is committed t...

Page 4: ...t for 24 hours For example use this function if some bufferwasaddedtothepool Presstoselect Presstosavechangeswhenadjustingsettings Presstoscrollthroughthefourusersettingmenus Add BioDoser dosing pump...

Page 5: ...esimmediately 5 Always power the BioDoser from a genuine Bionizer power adaptor or cable An incorrect adaptorcoulddamagetheBioDoserandwillvoid yourwarranty 1 WARNING alwaysusedilutedacidat1partacid to...

Page 6: ...netoothsaw 4 The Injection Tee must be fitted on the pipe that sends water back to the pool after it has been filtered the ReturnLine The Injection Tee should be installed LAST in the return line afte...

Page 7: ...COMPLETED The control box MUST be mounted vertically with the cables at the bottom in order to be weather resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty CO...

Page 8: ...n the same way as described in the Tee Piece Hose Installationsectionaboveandillustrationbelow AFTER ALL HOSE FITTINGS ARE COMPLETED TEST THE SYSTEM WITH FRESH WATER USING THE MANUAL DOSE FUNCTION PAG...

Page 9: ...ed Presstoalternativelyselect AUTO DELAY and OFF SET DOSE SIZE to enter 5 Minutes to 14 Use the and keys Days DOSING ON OFF KEY Alternatively press DOSING ON OFF to cancel withoutsaving Press PROGRAM...

Page 10: ...ff the pump cover Remove the Squeeze tube The rotor may come out but can be pushedbackinplace Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside LubricatingtheSqueezeTu...

Page 11: ...ube inside pump is not leaking Replace squeeze tube and orrollersasneeded seepage10 WARNING If any supplement has leaked out of hoses wash down the area with fresh water immediately Take the lid off t...

Page 12: ...Suite 410 Toll Free 1 855 8 IONIZE Phone 1 480 696 2387 Scottsdale AZ 85254 Web bionizer com 16427 N Scottsdale Rd USA Email relax bionizer com Bionizer Ltd Maroochydore Bioniser Pty Ltd 1 173 Bradman...

Reviews: