![bintec elmeg RM3000 Installation Manual Download Page 18](http://html1.mh-extra.com/html/bintec-elmeg/rm3000/rm3000_installation-manual_2752990018.webp)
or it is independent from the rest (such as lighting, etc.); it is highly recommended that all data devices
should be connected to the same power source. This will avoid operating and premature aging prob-
lems of drivers and other components.
3.5.2 Connecting
• Make sure that the device’s power supply switch is in the OFF position (0).
• Ensure that the power supply is NOT connected to either the electricity or the device.
• Connect all data cables.
• Connect the power supply cable to the device.
• Connect the power supply cable to the electricity supply.
• Set the router’s power supply switch on the ON position (1).
3.5.3 Disconnecting
• Make sure that the device’s power supply switch is in the OFF position (0).
• Disconnect the power supply from the electricity supply.
• Disconnect the power supply from the device.
• Disconnect the data cables.
3.6 RST Button
The different features of the RST button are described below.
3.6.1 Rebooting the device
Once the device is operating normally, pressing the RST button will make it restart.
3.6.2 Default Configuration
The RST button allows you to boot the device with its default configuration through the following steps:
• With the device switched off, keep the RST button pressed and switch on the router through the ON/OFF switch
(1).
• The PSU LED (green) will light up and the LED slot will begin to blink (amber). This blinking will continue for 10
seconds.
• For the device to boot with the default configuration, stop pressing the RST button while the LED slot is blinking
(i.e. before the 10 second period expires).
The router's default configuration sets the following access IP address and mask:
• IP address: 192.168.1.1
• IP mask: 255.255.255.0
Note
Some devices leave the factory with customized settings. This personalization may mean that the de-
fault configuration is different from the one shown above.
3.7 Connecting the data
The bintec RM3000 router family has the following data connections.
bintec elmeg