Manuale Operativo nr.
057-2-6-0001-R0
Versione 2017
Pag.40
PROBLEM
PROBABLE CAUSE
REMEDY
Operating on the
button panel the
lifting platform
does not
descend.
The emergency Stop Button
(red button on the built-in
lifting platform version) on
the button panel is inserted
Release the red button on the button panel
by turning it clockwise.
No voltage
Check the mains connection plug.
Improper operation of the
button unit on the button
panel
Replace the button unit.
Problems with the solenoid
valve which controls the
descent of the pump
Replace the solenoid valve (Figure 16).
IN CASE OF POWER FAILURE, USE THE SAFETY VALVE WHICH CAN BE OPERATED MANUALLY
BY TURNING IT COUNTERCLOCKWISE TO ALLOW THE DESCENT OF THE LIFTING PLATFORM.
Figure 16 – Electric Motor
Oil plug
Solenoid valve
Safety valve