OTHER
12
CAUTION
If the Angle Head is stored for an extended period after using a water-soluble coolant, it may be subject
to rust. Blow air through the Locating Pin to remove the remaining coolant and pour anticorrosion oil
from the Locating Pin prior to storage. Before using the unit again, depress the Locating Pin by hand to
check if it moves smoothly.
The Angle Head adopts non-contact seals. However,
assure to adjust the nozzles of the machine so that the
coolant directs not onto the unit but at the cutting tool.
Neglecting to do so may cause penetration of coolant
and internal damage.
CAUTION
If the unit is used for more than 30 minutes at a speed near the maximum spindle speed, please
cool by supplying air or coolant via the Stop Block.
Coolant feed to the cutting edge is achieved via a Stop Block which is connected to a coolant supply
pipe. Coolant flow through the Body Case contributes to the cooling of the unit.
[ The maximum coolant pressure is 1MPa (142PSI). ]
Coolant feed to the cutting edge
1