35
TROUBLESHOOTING
Issue
Solution
The fan jerks upon startup.
This is normal and may happen occasionally upon
startup. An initial slight jerking forward and backward
does not aff ect fan operation.
The fan will not start.
• Make sure the fan is receiving power. Check your
circuit breaker or fuse panel and wall switch for
functionality.
• Make sure supply power is adequate.
• Make sure all wires are securely connected and the
fan is properly wired and grounded.
• Make sure the plastic fi lm in the remote's battery tray
has been removed.
The fan wobbles.
• Make sure all mounting hardware is secure and tight.
• Remove the airfoils and make sure the colored dot
sticker on each airfoil matches the corresponding
sticker on the motor unit. If the stickers do not match,
move the airfoils to the matching attachment points.
• If you installed multiple fans, make sure the serial
numbers on the airfoils match the serial number on
the motor unit.
• Make sure all airfoils are aligned properly and are
securely fastened to the motor unit.
• If an airfoil is damaged, contact Customer Service.
Airfoils must be replaced as a set. Do not replace
individual airfoils.
• Universal Mount only
: Make sure the downrod and
motor unit are hanging straight. Raise the wiring
cover and locate the two bolts and nuts on the motor
bracket. Loosen the hardware slightly to allow the fan
to hang straight, and then re-tighten just past hand
tight. Slide the wiring cover back in place.