16
UNIVERSAL MOUNT INSTALLATION
11. Wire fan
WARNING
Disconnect power to fan location before wiring fan.
Do not connect fan to a damaged power source. Do not attempt to resolve
electrical failures on your own. Consult a qualifi ed electrician if uncertain of the
electrical installation of this fan.
Wire fan as shown on the following pages using the wire connectors. If your fan
packaging did not include an EMI fi lter, refer to Fig. 11a. If your fan packaging included
an EMI fi lter, refer to Fig. 11b.
The EMI fi lter is included only for certain regions and fan
diameters.
Attach green and yellow ground wire to mounting bracket with the unpainted screw.
Connect wiring harness from power supply to wiring harness from downrod, making
sure that the wiring and safety cable are routed in the same direction.
Carefully tuck wiring into outlet box or building structure. Ensure wire connectors are
turned upward and that wires are spread apart with grounded conductors on one side
of the outlet box/mounting structure and ungrounded conductors on the other side.
Supply Power Wire Colors
North America
100–120 V
Australia
All other regions
AC Hot/L1
Brown
Black
Brown or Red
Brown
AC Neutral/L2
Blue
White
Black or Light Blue
Blue
PE/Earth Ground
Green with Yellow
Green or Bare
Copper
Green with Yellow
Green with Yellow
Wire Connector Operation
1
2
Summary of Contents for HAIKU MK-HK4-041806
Page 1: ...Installation Guide Guide d installation Gu a de instalaci n bigassfans com HAIKU...
Page 41: ...FRAN AIS...
Page 81: ...ESPA OL...
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ...bigassfans com HKU INST 391 MUL 01 REV A 07 13 2022...