background image

 

 

page 1 of 6 

 

Operating manual 

 
DV5212/2N 
 
 

 

Product type, manufacturing date (calendar week/year of construction) 
and if required, conformity mark can be found on the nameplate on the 
product. 
Please provide us with the contents of the nameplate when making 
enquiries about the product. 
 
ebm-papst St.Georgen GmbH & Co. KG 
Hermann-Papst-Straße 1 
D - 78112 St.Georgen 
 
Phone: +49 (0) 7724 / 81-0 
Fax: +49 (0) 7724 / 81-1309 
 
[email protected] 
www.ebmpapst.com 
 
As per: 03.03.2017 
Version: 1 7 
Article number: 9694340034 
 
 

Original operating manual 

 

INDEX 

1

 

SAFETY REGULATIONS AND INFORMATION 

1

 

2

 

INTENDED USE 

3

 

3

 

TECHNICAL DATA 

3

 

4

 

CONNECTION AND COMMISSIONING 

4

 

5

 

FAULTS, POSSIBLE CAUSES AND REMEDIES 

5

 

6

 

COMPLIANCE 

5

 

 
 

1  SAFETY REGULATIONS AND INFORMATION

 

 
Read the operating manual carefully before commencing work at the 
product. Pay attention to the following warnings to avoid risk to 
persons or malfunctioning. 
This operating manual is an integral part of the product. 
In the event of resale or change of ownership the operating manual 
must accompany the product. This operating manual may be copied 
and provided as information on potential risks and their avoidance. 
 
Hazard classification of warning notices 
 
The following risk ratings are used in this operating manual to denote 
potential risk situations and important safety instructions: 

 

 

DANGER 
This is a potentially dangerous situation 
and warns of an impending health risk 
or risk of fatal injury if this warning is 
not observed. Observe this warning. 

 

WARNING 
The dangerous situation can occur and 
can result in major or fatal injuries if the 
warning is not observed. Work with 
extreme care. 

 

CAUTION 
The dangerous situation can occur and 
can result in minor injuries or damage 
to property if the warning is not 
observed. 

 

NOTE 
A potentially dangerous situation can 
occur and results in damage to 
property if not avoided. 

 
Qualification of personnel 
 
Only skilled electricians are permitted to install the product, to carry out 
the test run and to work at the electrical unit. 
Only instructed and authorized skilled personnel are permitted to 
transport, unpack, operate and service the product. 
 
Basic safety regulations 
 
Safety risks related to the product must be reassessed after installing 
in the final device. 
The operating manual was developed in accordance with European 
market requirements and may need adapting to the market 
requirements of the country in question. 
 
When working at the product, observe the following: 
 

 

Do not make any changes to the product. 

 

 

WARNING 
Impermissible high load 

 

 

Stop the product immediately after 
impermissible loading (e.g. impact, 
heat, overvoltage). 

 
 

Summary of Contents for DV5212/2N

Page 1: ...sk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed Work w...

Page 2: ...loose fitting garments or jewellery when working on moving parts Protect long hair by wearing a hair net WARNING Parts transported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spre...

Page 3: ...ith fully or partially dismantled or manipulated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign ...

Page 4: ...e system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted Requirements Before connecting the product ensure that the supply voltage corresponds with the product volta...

Page 5: ...inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this document is intended as Mounting instruc...

Page 6: ......

Reviews: