BIEMMEDUE EK 10C Instruction Manual Download Page 11

 

EN

 

11 

selected temperature level is reached, the fan only goes on for 
some time. 

 
SAFETY THERMOSTAT MANUAL RESET 

A temperature-limit thermostat will stop power feeding in case of 

overheating. If the thermostat releases, disconnect fan electricity, 
wait until the

 

fan has cooled and fix the problem causing 

overheating. 

To reset the temperature-limit thermostat, remove the cover and 

press the switch (2). 

 

MANTEINANCE 

Warning 

Before carrying out any maintenance operation you 

must: 

•   Stop the heater; 
•  Turn off the disconnecting switch on the electric 

switchboard; 

•   Wait until the heater has cooled down.  

 

CLEANING

 

For the heater to operate efficiently, cleaning operations must be 

carried out regularly. Dust and dirt may result in overheating and 
fire. 

DISPOSAL 

At the end of its useful life, you have to scrap and dispose of this 

product by taking it to a local differentiated waste collection center 
in conformity to law. 

Before scrapping, check the serial number plate on the machine: 

if it has the symbol, it means that disposal is regulated by EU 
Directive 2003/96 (Waste Electrical and Electronic Equipment, 
WAEE). 

The user must inquire about the local electrical and electronic 

waste collection system and follow its instructions. 

Illegal disposal of this product with normal domestic waste can 

seriously harm the environment and health and is subject to 
administrative penalties. 

 

 
 

 
 
 
 

OBSERVED FAULTS, POSSIBLE CAUSES AND REMEDIES

 

 

OBSERVED FAULT 

CAUSE 

REMEDY 

• Check mains, it should be 

• No electrical current 

• Check proper positioning and 
functioning of switch 

• The fan doesn’t start 

• Winding of motor burnt or interrupted  • Replace motor 

• Wrong setting of room thermostat 

• Check correct setting of room 
thermostat 

• The fan starts but there is not enough 
heat 

• Defective room thermostat 

• Replace room thermostat 

• The space heaters stops  

• Safety thermostat intervenes 

• Identify the problem that caused the 
overheating 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EK 10C

Page 1: ...GENERATORI D ARIA CALDA GENERATEURS D AIR CHAUD WARMLUFTERZEUGER SPACE HEATERS EK C L L 155 03 BM MANUALE D USO E MANUTENZIONE MANUEL D INSTRUCTIONS BEDIENUNGSANLEITUNG INSTRUCTIONS MANUAL...

Page 2: ......

Page 3: ...TATO DI SICUREZZA R ARMEMENT MANUEL DU THERMOSTAT DE S CURIT MANUELLE R CKSETZUNG DES SICHERHEITSTHERMOSTATS OVERHEATING THERMOSTAT MANUAL RESET 3 INTERRUTTORE PRINCIPALE INTERRUPTEUR MARCHE ARRET EIN...

Page 4: ...isiche sensoriali o mentali o prive di esperienza e conoscenza a meno che siano state supervisionate o istruite riguardo all uso dell apparecchio da una persona responsabile della loro sicurezza ISTRU...

Page 5: ...caldamento ed incendio SMALTIMENTO Al termine della vita operativa questo prodotto deve essere rottamato e smaltito consegnandolo al sistema di raccolta differenziata locale secondo le disposizioni di...

Page 6: ...t appareil n est pas pr vu pour tre utilis par des personnes atteintes d un handicap physique sensoriel ou mental ou ne poss dant pas l exp rience ou les connaissances n cessaires son utilisation Le c...

Page 7: ...surchauffe et incendie MISE AU REBUT Au terme de sa vie cet appareil doit tre achemin vers un centre local de collecte et de tri en respectant scrupuleusement les dispositions l gislatives en vigueur...

Page 8: ...ter stets abgeschaltet werden Achtung Dieses Ger t ist nicht geeignet f r die Benutzung durch Personen mit verminderten physischen sensorischen und geistigen F higkeiten oder ohne Erfahrung und Kenntn...

Page 9: ...ub und Schmutz zu berhitzung und Brandgefahr f hren kann ENTSORGUNG Dieses Erzeugnis ist am Ende seiner Betriebszeit zu verschrotten und zu entsorgen Hierzu ist es gem den geltenden Gesetzesbestimmung...

Page 10: ...o use the equipment by the person responsible for its safety INSTALLATION INSTRUCTIONS Warning The installation must only be performed by professional and skilled personnel Before switching on the hea...

Page 11: ...ocal differentiated waste collection center in conformity to law Before scrapping check the serial number plate on the machine if it has the symbol it means that disposal is regulated by EU Directive...

Page 12: ...RU 12 MOD 3 kW 3 4 o o 3 MOD 10 kW 15 kW 3 o B o C 5 o D 5 o A 5...

Page 13: ...RU 13 1 2 2002 96 Waste Electrical and Electronic Equipment WAEE...

Page 14: ...BG 14 3 kW 3 4 o o 3 10 kW 15 kW 3 o o C 5 o D 5 o 5...

Page 15: ...BG 15 1 3 kW 10 kW 15 kW 2 151 25 07 2005 2003 96 EC Waste Electrical and Electronic Equipment WAEE...

Page 16: ...DI SICUREZZA A RIARMO MANUALE THERMOSTAT DE SECURITE A REARMEMENT MANUEL SICHEREITSTHERMOSTAT MIT MANUELLER ENTRIE GELUNG LIMIT THERMOSTAT WITH MANUAL RESTART TA TERMOSTATO AMBIENTE THERMOSTAT D AMBIA...

Page 17: ...ICUREZZA A RIARMO MANUALE THERMOSTAT DE SECURITE A REARMEMENT MANUEL SICHEREITSTHERMOSTAT MIT MANUELLER ENTRIE GELUNG LIMIT THERMOSTAT WITH MANUAL RESTART TA TERMOSTATO AMBIENTE THERMOSTAT D AMBIANCE...

Page 18: ...olazione R glages possibile Regelungs m glichkeit Control options kW 1 5 3 0 6 66 10 0 10 0 15 0 MAX Corrente elettrica Courant lectrique Elektrischer Strom Electric current A 12 0 13 5 21 0 Portata d...

Page 19: ...19...

Page 20: ...20...

Reviews: