TECHNICAL INFORMATION
Gas rate maximum
Natural G20
m
3
/h
1,69
Propane G31
kg/h
1,24
Gas rate minimum
Natural G20
m
3
/h
0,65
Propane G31
kg/h
0,47
Gas restrictors references
Ø mm
/100
Natural G20
565
Propane G31
430
Air/gas mixer restrictors
Natural G20
Fuch-
sia
Fucsia
Propane G31
Fuch-
sia
Fucsia
Electrical data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
94
Protection degree
IPX5D
External fuse rating
A
3
Internal fuse rating
A
N° 2 - 2
AF
Flue design
Boiler type
B23P C13 C33 C43 C53 C63 C83
ø Coaxial
mm
60/100
ø Twin split pipes
mm
80/80
ø Roof
mm
80/125
Nominal heat flow rate
(A) (E)
kW
16,0
Exhaust temperature
(E)
°C
72,0
Mass flow rate
(E)
kg/s
0,0068
Flue gas figures
Nominal heat input
(A) (E)
kW
16,0
CO
2
content with gas G20
%
9,2-9,8
O
2
content with gas G20
%
3,9
CO content with gas G20
ppm
84,0
Exhaust temperature
(E)
°C
72,0
NOx class
5
Weighted NOx
ppm
30
(E)
Values refer tests with a 1 m flue working at the
nominal heat input
CO
2
contents
Nominal heat input
(A) (E)
kW
16,0
CO
2
content with gas G20 (range
min - max)
%
9,2-9,8
CO
2
content with gas G31 (range
min - max)
%
9,9-10,8
Minimum heat input
(A) (E)
kW
5,8
CO
2
content with gas G20 (range
min - max)
%
8,7-9,3
CO
2
content with gas G31 (range
min - max)
%
9,4-10,4
Other specifications
Height
mm
700
Width
mm
400
Depth
mm
290
Weight (dry)
kg
30,0