- 11 -
USE
APPLIANCE DESCRIPTION
The ignition of the
key, the arrow, M,
and the month (1 or
2) indicates the next
due date for mainte-
nance.
The flashing of the
symbol, the arrow, M
and 0 indicates that
the maintenance pe-
riod has expired
Temperature meas-
urement unit
Flashing: down (be-
fore flame detection)
Constantly illumi-
nated: flame present
and modulation level
Constantly illumi-
nated: lockout error.
The boiler can be
restarted by the user
by pressing the re-
set button
Non resettable error
The back lighting
has to be flashing
Constantly illuminat-
ed: set value
Constantly illumi-
nated: temperature
is displayed without
decimals but with
a sign (probe con-
nected)
Indicated
boiler
pressure
Constantly illuminat-
ed: remote control
connected
Flashing:
request
from remote control
in process
Constantly illuminat-
ed: pump active
The icon remains on
for post-circulation
Constantly illuminat-
ed: boiler antifreeze
active
Antifrostat
Constantly illumi-
nated: (system anti-
freeze active
SIGNAL DISPLAYED BY THE LCD
LCD
FUNCTION
E01
+
Lack of burner ignition
on safety lockout
E02
+
Safety thermostat inter-
vention lockout
E03
+
General lockout
E04
+
Little pressure in the
system or pressure
transducer disconnect-
ed
E05
+
Pressure switch anom-
aly (if present)
E06
+
Faulty c.h. temp. probe
NTC1 or NTC2
E08
+
Faulty external temp.
probe NTC (with K set)
E09
+
Faulty flue temp. probe
NTC (if present)
E10
+
Flue probe intervention
lockout (if present)