16
SIRIO
1
1
OFF
ON
6.4 Starting up of the unit
The distributor is equipped with a safety switch (Fig. 6.9) that
disconnects the machine whenever the door is opened (see wiring
diagram).
Therefore, if necessary, open the door or disconnect the plug
from the machine socket.
The terminals of the power cable (Fig. 6.10 - pos.
1) and the service switch inside the distributor (Fig.
6.11 - pos. 1) however remain live.
- For some operations it is however necessary to operate with
the door open but with the distributor connected.
It is possible for installation technician, to operate in this way,
by inserting the special plastic key, supplied with the distributor,
into the door switch and rotating it 90° (Fig. 6.12)
The opening and possible connection of the distributor
with door open (unless it involves cleaning operations) is
to be undertaken solely by personnel authorized to
undertake such operations.
Dont leave the distributor open and unguarded.
The safety element disconnection key is to be kept under the
exclusive responsibility of the installation technician.
Every time the distributor is switched on a diagnosis cycle is
undertaken which checks the position of the moving part, as well
as the presence of water and products.
Fig. 6.9
Fig. 6.10
Fig. 6.11
OFF
ON
Fig. 6.12
Summary of Contents for SIRIO FRESH BREW