70
ALARMS
DESCRIPTION
TYPE OF INTERVENTION
EDF Spoons
It occurs if the 10” spoon timeout lapses.With
this signalling on, no spoon will be dispensed.
Installer
ELC Capacity
Dispensing of instant products or hot water: it
occurs if a quantity of water between 50% and
70% of the programmed dose is dispensed. The
display will show the character ‘*’ as last cha-
racter. This signalling will prevail on the decoun-
ter signallings (the eight signallings below)
Installer
Air pump
It occurs if during the check at the end of the
dispensing from the Fresh Brew group the com-
pressor cannot reach the pressure of 0.3 bar in
3 seconds for the circuit. The display will show
the “Instant products only” message.
EFB Cleaning fi lter
It occurs if the value of the cleaning fi lter de-
counter is equal to zero.
Maintenance operator
EDZ Grinding blades
It occurs if the value of the coffee grinding blade
decounter is equal to zero.
Maintenance operator
EEC FB 1 fi lter
It occurs if the value of the FB 1 fi lter decounter
is equal to zero.
Maintenance operator
EEC FB 2 fi lter
It occurs if the value of the FB 2 fi lter decounter
is equal to zero.
Maintenance operator
EEC Esp Filter
It occurs if the value of the coffee fi lter decounter
is equal to zero.
Maintenance operator
EFI Decount EV
It occurs if the value of the EV decounter is
equal to zero.
Maintenance operator
EEL Gaskets
It occurs if the value of the coffee gasket de-
counter is equal to zero.
Maintenance operator
EDO Boiler 1
It occurs if the value of the boiler 1 decounter
is equal to zero.
Maintenance operator
EDO Boiler 2
It occurs if the value of the boiler 2 decounter
is equal to zero.
Maintenance operator
OAR HACCP
It occurs if the value of the HACCP decounter is
equal to zero.
Maintenance operator
EDJ decount PX
It occurs if the X powder decounter is
000000s.
Maintenance operator
EDJ decount Gr
It occurs if the bean decounter is 000000s.
Maintenance operator
ECQ Driver OxxPxx
It occurs when a failure is found on output OUT
XX (Oxx) on pin XX (Pxx).In case of intervention
of OMNIFet overcurrent protection, Gate voltage
must be read after50 ms.
Installer