18
Fig. 4.5
Fig. 4.6
Fig. 4.3
Fig. 4.4
Fig. 4.2
Fig. 4.1
4.0 INSTALLATION
4.1 Positioning
– If positioned near to a wall, there must be a minimum distance
from the wall of at least 5 cm. (Fig.4.1) so as to allow a regu-
lar ventilation. In no case cover the distributor with cloths or
similar.
– Position the distributor, checking the leveling by means of the
adjustable feet already assembled on the machines (Fig.4.2).
make sure that the distributor doesn’t have an inclination of
more than 2 degrees.
WARNING!
Do not position the device near infl ammable
objects, keep a minimum safety distance of 30 cm.
Bianchi Vending Group spa
declines all responsibility for in-
conveniences due to the non observance of the above mentioned
installation norms.
If the installation is made in safety evacuation corridors make
sure that with the distributor door open there is anyhow suffi cient
space to pass by (Fig.4.1).
So as to avoid that the fl oor gets dirty, due to accidental spilling of
the products, use, if necessary, under the distributor, a protection
suffi ciently wide to cover the distributors’ operating space.
6.2 Connection to the main water supply
Before proceeding with the connection of the distributor
to the water main supply verify the following water cha-
racteristics:
– that it is drinkable (eventually through an laboratory’s analysis
certifi cation)
– it has a pressure comprised between 0.5 and 6.5 (bar) ( if this
should not be the case, use a pump or a water pressure, reducer
according to the case).
– install, if not present, a tap in an accessible position to isolate
the machine from the water mains should it be found to be
necessary (Fig.4.3).
– before making water connections, make some water fl ow out
of the tap so as to eliminate possible traces of impurities and
dirt (Fig.4.4)
– connect the cock to the distributor, using a pipe in nylon material
suitable for food products and suitable for the mains pressure.
In the event of the use of a fl exible pipe it is necessary to fi t
the reinforcement bush supplied inside (Fig. 4.5).
– the foreseen connection is a 3/ 8 gas (Fig.4.6).