39
5.3.3 ‘Preselections’ Menu
All push buttons can be used as preselection:
Push button 01…30
Without product
Product
[0…9] 0= disabled
This type of preselection allows to select
the relevant product. When this preselec-
tion is pressed the fi rst 3 characters on the
display are reserved to the wording “NO “.
The remaining 10 characters will display the
product to be entered using the “graphic con-
fi guration” window of the windows program
of the current software.
For example, if the product is Milk, the mes-
sage will be “NO milk”. The function of this
preselection is to set to zero the programmed
dose in the drink of the relevant instant pro-
duct. There can be several selections of this
type coupled to different products.
Double product
[0…9] 0= disabled Applicable only for drinks
with espresso or instant coffee. It replaces
the coffee with the selected instant drink.
INC+ / DEC - Sugar
T sugar [0…25.5 s]
H
2
O
[0…25.5 s] o [0…999 cc] For instant drinks only
DEC- key? 01…30 Select DEC- key and STOP, if required.
Fixed in line 2? Management of sugar bar always on
the second line instead of wording Ready [On/Off] If
ON the alarm signals are not displayed in the second
line. If this option is ON, it prevails on any type of
alarm signal usually displayed in line 2 (e.g. without
coffee).
Increase product: with this type of preselection it is
possible to program the instant product, a time for
the instant prodcut, a dose of water and the enabling
“fi xed in line two”.
If the fi xed in line 2 option is enabled, it means that
the bar of the 8 squares is always displayed in line 2
to the user in ready status. The calculation of the fi nal
dose, should a user press the preselection, is given
by the fraction of the black squares over the total (8)
by the sum of the doses programmed on the drink
and the dose programmed on the preselection. The
calculation of the water dose is not implemented as
there is some doubts about how to manage it.
Decrease product: linked to the Increase product pre-
selection and is used to decrease the black squares.
Therefore the parameters related to this preselection
are the same as the “Increase product” preselection.
N.B. There can be only one “Increase/Decrease pro-
duct” preselection.
PAN cycle:
Upon switching on the distributor, the cycle provides that if the
probe detects an inner temperature > than the safety temperature,
the selections will be stopped.
Within a limit time of 30 sec., signalled by the buzzer activation,
the alarm can be inhibited by setting the code 98 on the alphanu-
meric keyboard. The temperature alarm will remain inhibited for
the programmed safety time, then the safety temperature control
will be enabled again. If upon switching on the detected tempera-
ture is < than the safety temperature (non alarm condition), the
control of this temperature is immediately enabled.
This alarm can be set to zero in both maintenance mode and by
switching off and switching on again the machine, by entering the
code 98 within 30 sec. of buzzer operation.
If the inner temperature reaches the value set as safety value,
the selections from 51 to 68 are stopped and automatically made
“NOT AVAILABLE”.
Temp.1 Tank Slave X
Temperature of probe 1 of Tank A [5÷15
°C for SNACK model and 1÷15 °C for PAN
model , >15 °C = Off] It sets the working
temperature of the distributor.The wording
Slave X indicates the slave number linked
to the MASTER distributor.
Delta Temp.1 Slave X
Temperature hysteresis of probe 1 of
cool A [1.0÷5.0 °C] It determines the interval
according to the programmed temperature
to enable and disable the compressor.The
wording Slave X indicates the slave number
linked to the MASTER distributor. Stored on
BVM600 board.
Offset temp.1 Slave X
Offset temperature of probe 1 Cool
A [-5÷5 °C] The wording Slave X indicates
the slave number linked to the MASTER
distributor. Managed by WinBianchi Level
Development only. Stored on BVM600 board.
Modifi able by Bianchi only.
Temp.2 Tank Slave X
Temperature of probe 2 of Tank A [5÷15
°C for SNACK model and 1÷15 °C for PAN
model , >15 °C = Off] It sets the working
temperature of probe 2 of the distributor. If
it has to cool it switches on the fan output in
the new board with 2 probes. The wording
Slave X indicates the slave number linked
to the MASTER distributor. Displayed only if
Cool Distributor Probe is 2.
Delta Temp.2 Slave X
Temperature hysteresis of probe 2,Cool
A [1.0÷5.0 °C] It determines the interval
according to the programmed temperature
to enable and disable the compressor.The
wording Slave X indicates the slave number
linked to the MASTER distributor. Displayed
only if Cool Distributor Probe is 2.Stored on
BVM600 board.
Offset temp.2 Slave X
Temperature offset of Probe 2, Cool
A [-5÷5 °C] The wording Slave X indicates
the slave number linked to the MASTER
distributor. Managed by WinBianchi Level
Development only. Displayed only if Cool
Distributor Probe is 2.Stored on BVM600
board. Modifi able by Bianchi only.
Delta Safety Slave X
Delta cool safety A [5÷50 °C] Enabled
only in PAN confi guration, it determines the
safety temperature.The wording Slave X indi-
cates the slave number linked to the MASTER
distributor. Managed by WinBianchi only.
T Safety Slave X T Cool safety A [1÷9 ore] Interval expressed
in hours within which the selections of the
2 bottom cabinest are still available despite
the cell temperature is higher than 7°C
(safety temperature), for example after the
installation or loading of the distributor. The
wording Slave X indicates the slave number
linked to the MASTER distributor. Managed
by WinBianchi only.
Defrost after Slave X
Defrost frequency Cool A [1÷12 hours]
Interval expressed in hours in order to de-
frost the radiator. The wording Slave X indi-
cates the slave number linked to the MASTER
distributor. Managed by WinBianchi only.
Defrost for Slave X Defrost duration Cool A [1÷30 minutes]
Interval expressed in minutes determining
the duration of the deactivation of the com-
pressor for defrosting.The wording Slave
X indicates the slave number linked to the
MASTER distributor. Managed by WinBianchi
only.