–  The second format “Operators” includes the list of the operators 

in charge of the maintenance of the different distributors, with 
relevant data (address, telephone number, E-mail,etc.)

By clicking twice on one of the operators in the list a window will 
appear similar to the previous one showing as additional options 
the possibility to modify any fi eld and not only the form note 
using the EDIT key and the possibility to enter a new operator 
by pressing ADD NEW key; this insertion must be confi rmed  by 
pressing OK  key.

–   The third format “Sale Point” includes the list of the customers 

having at least one distributor enabled for the telemetry service, 
with the data to track them; similarly to the operators format, 
by clicking twice on one of the customers in the list a window 
will appear showing the different fi elds and giving the same 
possibilities of intervention as the previous window.

-   The fourth format “Vending Machine” includes the list of the 

distributors with the following fi elds: “Description” specifying 
the type of machine; “Serial number” specifying the serial 
number; “GSM” specifying the number of SIM board installed 
in the machine; “Sale point” specifying the customer where the 
distributor is installed; “Operator” specifying the technician in 
charge of that specifi c distributor and fi nally “Notes” including 
the comments, if any

–   By clicking twice on one of distributors in the list, a window will 

appear showing, as the previous windows, the previously listed 
fi eld, the major difference lying in the fact that if a data sheet 
is modifi ed with Edit key or a new distributor is added with Add 
New key, the Sale Point and Operator fi elds will allow you to 
enter only one of the corresponding items listed in the formats 
described above, while in the Description item one of the types 
of machine listed in the pull-down list must be selected.

NB: if new elements must be added to the list of distributor, fi rst 
of all it will be necessary to enter the new Operators and Sale 
Points in the corresponding formats and then the new Vending 
machines; the above to avoid that when  the operator and sale 
point data are coupled, in the creation of the new vending machine 
there will be no possibility to try and enter any item not included 
in the insertion list.

Important: 

When a new Distributor is added in the “Communica-

tion GSM” fi eld  I must ABSOLUTELY enter the number with +39 
at the beginning.

Send SMS Section

This section gives the possibility to send an SMS by writing in the 
window with the portable phone icon the number of the receiver 
and entering the message text in the bigger window; in the top  
right hand corner  there is also a counter showing the number of 
characters entered (2nd number) as well as the total number of 
available characters (1st number).

At the end of the message text, this will be sent to the selected 
number by pressing SEND key.

Status Section

This section provides some information about the Modem and 
the connection and in particular about the operator of the board 
inserted in the Modem (“Operator” fi eld) and the “Signal Quality” 
fi eld providing  an indication of the current power of the network 
signal.

Summary of Contents for BVM952

Page 1: ...BVM972 BVM952 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...0335 2 75 2003 06 Special requirements for commercial dispensers and automatic vending machines EN ISO 11201 EN ISO 3744 Measurement of acoustic noise 2 ELECTROMAGNETIC COMPATIBILITY EMC EN 55014 1 Em...

Page 4: ...its service life to the appropriate separate collection centres for electronic electrotechnical waste products or return it to the dealer when purchasing a new equivalent equipment The appropriate se...

Page 5: ...ned as the person responsible for the installation of the automatic distri butor the starting up operations and the function settings Each regulation operation is the exclusive responsibility of the i...

Page 6: ...SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Te on small size for Trimmer regula tion RATCHET SPANNER no 14 TESTER ELECTRICIAN S SCISSORS PROGRA...

Page 7: ...duct loading 4 6 1 Product container loading 4 6 2 Cup loading 4 6 3 Spoon loading 4 6 4 Spent coffee grounds bag insertion 4 7 Automatic distributor layout 4 8 First self installation mode 5 0 SOFTWA...

Page 8: ...as such must always remain inside of the same so as to allow further consultations on the part of the various operators until the dismantlement and or scrapping of the machine In case of loss or dama...

Page 9: ...e user must not in any circumstance be able accede to those parts of the automatic distributor that are protected and require a tool in order to be accessible The knowledge and the absolute respect fr...

Page 10: ...mm 1620 mm Width B 666 mm 666 mm Depth C 776 mm 776 mm Weight 140 kg 190 kg 3 155 kg Power Supply V230 V230 Power frequency Hz 50 Hz 50 Installed power 1 1 8 kW 3 2 kW 1 8 kW 3 2 kW Nominal current Ma...

Page 11: ...1 2 1 Coffee group and grinder 2 Drink dispensing group 3 Sugar dispenser group 4 Payment system 5 Cup column 6 Electronics board CPU 7 Power card 8 Spoons column 9 Water softener lter 10 Water bin 1...

Page 12: ...d grinder 2 Drink dispensing group 3 Sugar dispenser group 4 Payment system 5 Cup column 6 Electronics board CPU 7 Power card 8 Spoons column 9 Water softener lter optional 10 Water bin 11 Dispensing...

Page 13: ...rate and make the cup fall into the cup ring inside the cup dispenser Fig 2 1 2 1 2 SUGAR DISPENSER The sugar is dispensed directly in the cup in the E versions whereas for the I versions it is pre mi...

Page 14: ...the brew chamber the rotation group geared motor brings it into the dispensing position and simultaneously compresses the ground coffee Fig 2 4 Fig 2 5 the pump that dispenses the quantity of program...

Page 15: ...al of the various processes described here below can be activated If present the whipper motor is activated Fig 2 8 The electro valve xed on the soup boiler Fig 2 9 or on the coffee boiler Fig 2 10 it...

Page 16: ...les and by a transparent lm in polypropylene Fig 3 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environme...

Page 17: ...ents listed here below cup turret example in Fig 3 7 coin box sugar container weight on the spoon dispenser column coin mechanism cover Master board product containers water bin oat mechanism bottom s...

Page 18: ...ts dirty due to accidental spilling of the products use if necessary under the distributor a protection suf ciently wide to cover the distributors operating space 6 2 Connection to the main water supp...

Page 19: ...reason verify the plant s earth wire connection to ascertain that it is ef cient and it answers national and European safety electric standards If necessary require the intervention quali ed personne...

Page 20: ...some operations is however necessary operate with the door open but with the distributor connected It is possible for installation technician to operate in this way by inserting the special plastic ke...

Page 21: ...start to heat up water in the boiler SINGLE STAINLESS STEEL BOILER FOR SOUPS At the output of BV lines the distributor will be put in condition of FIRST INSTALLATION As soon it reaches the location t...

Page 22: ...n with a chlorine base products that can be purchased in pharmacies carefully fol lowing the indications on the product instruction labels remove all the product containers from the distributor Fig 4...

Page 23: ...llation open the board and coin mechanism protection door Fig 4 21 Connect the payment system Fig 4 22 to the Master board The selectors must be directly connected to the Master board the and the seri...

Page 24: ...ndicated on the label Fig 4 27 pay attention that they there are no clots avoid pressing the product and using an excessive quantity so as to avoid its aging in relation to the consumption forseen in...

Page 25: ...lumn is not aligned with the distribution outlet then ll all the columns proceeding in an anti clockwise sense opposite sense when the column is aligned with the distribution outlet close the door and...

Page 26: ...ve the wrapping Fig 4 31 once the loading is completed put the weight back in the spoon dispensing column Check that the spoon are cut burr free that they are not bent and that they are all placed hor...

Page 27: ...each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP S...

Page 28: ...ve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP SECOND SOUP EV1...

Page 29: ...most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP SECOND SOUP EV1 Broth 0 EV2 Tea 0 EV3 Coffee Sugar...

Page 30: ...ion can be combined creating a maximum sequence of 3 electrovalves each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributo...

Page 31: ...e combined creating a maximum sequence of 3 electrovalves each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we shou...

Page 32: ...e 3 way Coffee EV throughout the procedure The procedure will be carried out with resistance off At the end a date will be shown on the display For Instant boiler When the distributor is started up th...

Page 33: ...ine BVM970 BVM 950 BVM 921 BVM600 BVM470 Manag Cold X Selects the type of management of the cold compressor 0 Snack Pan Can Menu available only with machine type BVM600 BVM470 1 None Cold management n...

Page 34: ...ion Below are two examples of a machine with PAN con guration with the following data Tank temperature 2 Delta temperature 2 Offset temper 0 Delta safety 5 therefore safety temper 5 2 7 Safety time 2...

Page 35: ...Bianchi only Code Keyboard Enables the management of the alphanume ric keyboard for Hot Distributor On Off It enables the selection code in the Times and Doses Menu Code keyboard In the programming mo...

Page 36: ...e from last selection Q ty of water to be increased 3 ore 2 cc 6 ore 3 cc 9 ore 5 cc 12 ore 6 cc Type BVM600 Selects the type of management of cold compressor Snack Pan Menu available only with machin...

Page 37: ...ot with four full squares and four empty squares Given that the sugar management of this option follows the formula Sugar A B 8 Where A Sugar dose in the doses menu for every drink B Sugar dose in the...

Page 38: ...e 70 90 C The wording Slave X indicates the slave number linked to the MASTER distributor Managed by WinBianchi only Boiler Temp 2 Slave X Boiler 2 temperature Espresso boiler has a range 70 110 C Ins...

Page 39: ...hine by entering the code 98 within 30 sec of buzzer operation If the inner temperature reaches the value set as safety value the selections from 51 to 68 are stopped and automatically made NOT AVAILA...

Page 40: ...managed only on the selections enabled to this process Extra Coffee Time 0 5sec The user presses the Extra coffee or strong coffee preselection and then short coffee for example The Grinder will grind...

Page 41: ...oupled to 1 E V 0 25 5 s Ton product X T on motoreducer second product 0 25 5 s The selected drink will be prepared with the quantity of sugar requested by the user Every square corresponds to x sec o...

Page 42: ...to 3rd E V 0 25 5 Ton product X T on motoreducer third product 0 25 5s Toff product X T off motoreducer third product 0 25 5s T Sugar Espresso X T sugar espresso 0 25 5 s T Sugar MB T sugar 0 25 5 s o...

Page 43: ...product X T on motoreducer second product 0 25 5 s Toff product X T off motoreducer second product 0 25 5 s T product X T 3rd box coupled to 2 E V 0 25 5 s R product X 3rd box delay coupled to 3 E V...

Page 44: ...he machine will be blocked The microprocessor will read and store the date and time of mains lack When the distribu tor is switched on again when the power is restored the microprocessor will evaluate...

Page 45: ...e coin box cannot give the change the banknotes will not be accepted 2 Configuration MDB Coin box Cash less Banknote reader The reader is enabled only to recharge keys ON 1 Con guration MDB Coin box B...

Page 46: ...11 Promotions Menu Enable Promot Enables management of promotions 0 User Set 0 promotions disabled Promo cashless Enables management of promotions with a cahsless system On Off Promo coin Enables mana...

Page 47: ...on alphanumeric key board Menu enabled only if Promotion Set ON Select key selects promotion key 1 30 Select hot selects hot key 1 30 Select cold 1 selects code 1 A11 B68 Select cold 2 selects code 2...

Page 48: ...atically reset upon operator passage Dec Powder 1 Decounter value Powder 1 0 1677721s Dec Powder 8 Decounter value Powder 8 0 1677721s The decount value to be entered the Dec Powder X is determined by...

Page 49: ...ctions 0 16777215 Selections sect 11 Selection counter sector 11 0 65535 Selections sect 68 Selection counter sector 68 0 65535 Free Tot Free Unresettable total free 0 16777215 Tot Free Resettable tot...

Page 50: ...3 00 00 23 59 Cleaning 4 Sets time of cleaning 4 00 00 23 59 These sections can be set and displayed for the hot machine only 5 3 15 5 Disinfection T disinfection T disinfection 0 120s Disinfection d...

Page 51: ...ceive e mail messages also with the distributor error The e mail mes sage with the EVA TDS data is sent at the established time and therefore the clock chip is required At the end of this operation th...

Page 52: ...been stored in the program database The list includes the Number eld specifying the number from which the message was sent corresponding to a speci c distri butor the Date eld specifying date and time...

Page 53: ...ed eld the major difference lying in the fact that if a data sheet is modi ed with Edit key or a new distributor is added with Add New key the Sale Point and Operator elds will allow you to enter only...

Page 54: ...distributors stored in the program database the following data will appear type of machine Distributor Customer at which the machine is installed Sale Point and the operator in charge Operator Now yo...

Page 55: ...unctions which can be enabled by WinBianchi Direct selection keyboard Espresso version In the maintenance mode the keys have the following meaning 01 Group rotation 02 MDB tube lling 03 MDB tube deple...

Page 56: ...nds Mixer test Switches on the Mixers for 5 sec in the fol lowing order 1 2 3 4 5 6 Group rotation Makes a rotation of the coffee group Alarm scrolling Used to scroll installed alarms and signallings...

Page 57: ...th the provisions listed below 6 1 3 Daily cleaning recommended The objective is that to avoid the creation of bacteria in the food zone areas For all cleaning operations follow the instructions indic...

Page 58: ...d on entrust them to specially trained personnel For more complicated interventions such as removing the lime build up in the boilers a good knowledge of the equipment is necessary Monthly effect the...

Page 59: ...aintenance is in progress it is important that the person responsible for cleaning never has to interrupt his work in order to operate the machine For internal cleaning use clean cloths better if disp...

Page 60: ...6 4 1 Dosage and grinding regulations Coffee temperature in the cup between 70 and 80 Temperature of soup products in the cup between 70 C and 80 C Grammage of coffee powder between 6 and 8 grams gram...

Page 61: ...obtain a good rinsing of cups possibly act on the rate screw and then check that doses are reliable Fig 6 11 Automatic adjustment of grinding Fig 6 10 It allows in the expresso versions to keep grind...

Page 62: ...ispensing group towards outside g 6 13 Then act on the two handles shown in g 6 14 6 16 remove the panel and support it until completely taken out g 6 15 6 17 After carrying out maintenance operations...

Page 63: ...nt version Disassemble the mixer groups and loosen the three screws shown in gure 6 18 6 19 slide the frontal panel leftwards until the slots are released then remove the panel to access inside Mod 95...

Page 64: ...onut shells which are charred and activated in oven The activation process gives an exchange surface whose GAC can by alloying organic impurities to it such as disinfectants chlorine and pesticides su...

Page 65: ...ket can be used The operation can be effected on the distributor as follows switch off the machine turn the lower faucet being careful to put the relative hose in a bucket or better in a drain Fig 6 2...

Page 66: ...n lamp by carefully taking it out of its support Fig 6 24 After replacing the lamp make sure that it works After cutting off again the power supply of the machine as semble the parts in the reverse or...

Page 67: ...bed empty the liquid waste bin carefully eliminate the spent grounds bag clean with a cloth all the internal and external surfaces of the machine protect the outisde of the machine with a plastic lm w...

Page 68: ...his alarm is installed Installer EBI Translator It occurs if the 10 sec timeout lapses during the movement of the spout translator Installer 8 2 2 Non stored alarms EAJ Scale factor This alarm is acti...

Page 69: ...re credited only in case of instant grinding X 1 or 2 Installer EEK Group It occurs if the programmed coffee group timeout lapses The display will show the Without coffee message The amount is re cre...

Page 70: ...rs if the value of the FB 1 lter decounter is equal to zero Maintenance operator EEC FB 2 lter It occurs if the value of the FB 2 lter decounter is equal to zero Maintenance operator EEC Esp Filter It...

Page 71: ...BIANCHI VENDING GROUP S p A Corso Africa 9 24040 Localit Zingonia Verdellino BG ITALIA tel 39 035 419 67 11 fax 39 035 883 304...

Reviews: