Page 9
6.4
FOCUS COIL (not included)
They allow a higher intensity heating on a small area and are especially used for attaching to the
heated material.
1.
Connect the coil into the coil holder.
2.
Attach the coil on the material with the circular area of the coil.
3.
Press the button for a max. of 10 seconds.
4.
After heating the material, let the coil cool off for at least 50 seconds.
7
CONTROL LIGHTS
Lights on the device indicate the following states of the device:
Signals
Status
Green
Standby
Yellow
Heating in progress
Yellow blinking
Device is overheated
Red blinking
Bad coil or power overload
Red
Error
8
DESCRIPTION
Pos.
Description
1
Induction heater
2
Coil holder
3
Connection cord
4
Plastic case with protective lining
5
Cover fitted coils
6
Switch on and overheating indication light
7
Carrying strap
Pos.
Description
1
Induction heater
2
Coil holder
3
Connection cord
4
Plastic case with protective lining
5
Cover fitted coils
6
Switch on and overheating indication light