COMMISIONING
Before usage of the device, check the incoming cable, handle and the handle cable to assure that
they are not damaged.
1. Disconnect the device from the electric network and loosen the screws on the handle.
2. Insert the working coil into the holes in the clamping holder of the coils (handle, 2) and tighten the
locking screws on the sides.
3. Connect the supply cable of the device into a properly grounded standard socket ~230V, 50/60Hz
and turn on the device using the main switch. Before turning on, make sure that the handle is laid
in a safe place and that the heating button is not pressed down.
4. Attach or put the working coil on the material you want to warm up and press the button on the
handle. Heating remains activated during the pressing of the button - do not exceed the operating
cycle of 2 minutes of heating and 2 minutes of cooling.
5. After finishing the cycle, release the button on the handle and remove the heating coil from the
heated material.
NOTE
: During heating there should be a gap of around 3-5mm between the coil and the heated
material to avoid excessive wear of the heating coil. A gap larger than 3-5mm decreases heating
efficiency and extends the heating time.
After finishing heating, place the handle with the heating coil in a safe, inflammable place until the
heating coil is completely cooled. Then turn off the device using the main switch and disconnect it
from the electric network.
ATTENTION
: The coil and the heated object can reach a high temperature and/or cause burns or
result in fire.
6
DETACHABLE COILS
6.1
FRONT AND SIDE ATTACHABLE COILS
Application of the standard attachable front and side coils for the heating of nuts, couplings, gaskets,
hinges, exhaust mains, screws etc. which are accessible so as to allow the attaching of the coil.
The standard supplied diameters of
front attachable coils are 15 – 45 mm
The standard supplied diameters of
side attachable coils are 15 – 45 mm
NOTE
: The service life of the coils can be increased by cleaning rust, paint, oil etc. from
the heated material. During heating, there should be a gap around 3-5mm between the
coil and the heated material to avoid excessive wear of the heating coil. Holding of the
coil directly on the hot material can cause the burning of the coil insulation, thereby
shortening the service life of the coils. We recommend limiting direct contact of the coil
with the hot material to the minimum.
TIP! For loosening nuts, screws etc., it is not necessary to heat the material until it is
red hot. Heat the nut for 2 seconds and try to loosen it using a wrench. If it is not