2.6
ELECTRICAL SAFETY RULES
SYMBOL
EXPLANATION
This is a safety class I device, which may be supplied with power only from the power
outlet with a protective conductor, which must be connected to the device as first and in
any case must not be interrupted (e.g. by an extension cord). Any interruption of the
protective earth conductor, or its disconnection will cause a potential electric shock
hazard that can cause injury. Make sure that the device (device chassis) is properly
grounded.
Do not twist or sharply bend the power cord, as it may damage the internal wiring.
Never use BGS 3390 if the power cord shows any signs of damage. Keep the power
cord away from heat, oil, sharp edges or moving parts. Never repair the power cord – if
damaged, the power cord must be replaced. Damaged cords create a risk of electric
shock.
Before replacing the applicator (coil), disconnect BGS 3390 from the power source (wall outlet).
If you are not using BGS 3390, unplug the power cord from the power supply.
Caution: This product is for class A industrial use. It may cause radio interference in residential,
commercial and light industrial environments. This product is not intended for installation in residential
environment, business environment and light industry with connection to the public supply network;
user may be required to take adequate measures to reduce interference.
3
PERIODIC INSPECTION AND MAINTENANCE
Make sure the device is turned off, unplugged and cooled. Use a dry, clean cloth or paper towel to
remove grease, oil and other impurities from the machine, applicators and cables before placing BGS
3390 in the storage case.
Use freely available non-volatile cleaning agents for grease, oil and dirt that is difficult to remove.
Before the first reuse of BGS 3390 allow all components to air dry.
Do not immerse any part of the device in water or other liquids. Do not spray and wash the device
down with water spray. Do not clean the components with volatile organic compounds such as
gasoline, benzene, kerosene, methyl ethyl ketone (MEK), fuel oil, brake parts cleaners, paint and
thinner remover, varnish removers, self-adhesive solvents, etc. These substances cause fire and
cause hardening or dissolving of polymeric materials used in the device.
Do not use heat sources, heaters, burners, microwave ovens or gas furnaces, etc. for drying the
device and its parts after cleaning.
4
STORAGE
4.1
COOLING, DISMANTLING AND STORAGE
After completion of heating, make sure that the coil holder and coils used are placed in a safe place.
Handling the device or its parts before letting it cool down can result in injury, damage to the
equipment or fire.
After completion of heating, leave the device turned on for 10 more minutes – the device will be
cooled down by fans until cooled off completely and then will turn off the fans. Then shut it down by
the main power switch and disconnect it from the power supply.
If you unplug the unit immediately, let all working coils cool down for at least 15 minutes.
After cooling, place the device and its accessories in the case. Place the cords so as to avoid their
sharp bending or twisting – it could cause their damage.