INSTALLATION MANUAL
2) GENERAL INFORMATION
The SIRIO C MA 230 INV control panel comes with standard factory settings. Any
change must be made using the programmer with built-in display or universal
handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
- Control of 1 three-phase motor, with inverter
- Electronic speed control with inverter
- Obstacle detection
- Separate inputs for safety devices
- Configurable command inputs
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
TESTING
The SIRIO CMA 230 INV panel checks (tests) the safety devices (photocells) before
performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
220-230V 50-60Hz(*)
Low voltage/mains insulation
> 2MOhm 500V
Operating temperature range
-10 / +50°C
Thermal overload protection
Inverter
Dielectric rigidity
mains/LV 3750V~ for 1 minute
Obstacle detection with encoder
Present
Maximum motor power
750W
Accessories power supply
24V~ (demand max. 1A)
24V~safe
AUX 3/ Output for audible signal
NO contact (24V~/max.0,5A)
Flashing light
230V~ 40W max
Dimensions
146x170x60mm
Fuses
see Fig. B
N° of combinations
4 billion
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
Install the electrical system referring to the standards in force for electrical systems
CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
5) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
6) DO NOT EDIT INVERTER SETTINGS. PROGRAMMING TO BE
CARRIED OUT VIA SIRIO CBA 230 INV CARD ONLy
Terminal
Definition
Description
Po
w
er
supply
L
LINE
Single-phase power supply 230V~ ±10%, 50-60Hz
N
NEUTRAL
Au
x
20
LIGHT 230V
Flashing light 230V output max. 40W
21
26
AUX 3 - FREE CON-
TACT (N.O.)
(Max. 24V 0,5A)
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN
ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK.
Refer to “AUX output configuration” table.
27
M
ot
or 1 limit swit
ch
41
+ REF SWE
Limit switch common
42
SWC
Closing limit switch SWC (N.C.)
43
SWO
- Opening limit switch SWO (N.C.)
A
cc
essories
po
w
er supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
Commands
60
Common
IC 1 and IC 2 inputs common
61
IC 1
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
62
IC 2
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
63
Common
IC 3 and IC 4 inputs common
64
IC 3
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
65
IC 4
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
WIRING AND TERMINAL BOARD CONFIGURATION
10 -
SIRIO CBA 230 INV
D811948_01