INSTALLATION MANUAL
Logic
Definition
Default
Cross out
setting
used
Optional extras
HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
IBL OPEN
Block pulses during
opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
|IBL TCA
Block pulses during
TCA
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
IBL CLOSE
Block pulses during
closing
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (Fig.G Rif. 1).
1
Opens in other direction to standard operating mode (Fig. G Rif.2)
SAFE 1
Configuration of
safety input SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
SAFE 3
Configuration of
safety input SAFE 3.
77
2
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2 (Not active on SAFE 3).
IC 1
Configuration of
command input IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
IC 2
Configuration of
command input IC 2.
62
4
2
Input configured as Open.
3
Input configured as Close.
IC 3
Configuration of
command input IC 3.
64
2
4
Input configured as Ped.
5
Input configured as Timer.
IC 4
Configuration of
command input IC 4.
65
3
6
Input configured as Timer Pedestrian.
AUX 3
Configuration of
AUX 3 output.
26-37
0
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
FIXED CODE
Fixed code
0
0
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
14 -
SIRIO CBA 230 INV
D811948_01