LaserSpeed 8000/9000 I/O Module Instruction Handbook
Operation
Part No. 93342 / Drawing No. 0921-01516
Page 67 of 84
Revision E (Dec 2013)
55 (msb)
56
57
58 (lsb)
3.4
3.5
Walking Threshold
32-bit unsigned integer
Walking Threshold Setting
Serial Command: "W"
59 (msb)
60
61
62 (lsb)
3.6
3.7
Minimum Final
Length
32-bit unsigned integer
Minimum Final Length Setting
Serial Command: "X"
63 (msb)
64
65
66 (lsb)
3.8
3.9
Gauge Temperature
32-bit unsigned integer
Current Gauge Temperature
Serial Command: "I"
67 (msb)
68
69
70 (lsb)
3.10
3.11
Material Present
Threshold
32-bit unsigned integer
Material Present Threshold Setting
Serial Command: "M"
71
4.0
Reserved
8-bit byte - Don't use (set to 0)
72
4.1
Baud Rate
8-bit byte
Baud Rate Setting
Serial Command: "J"
73
4.2
Filter Lockouts
8-bit byte
Filter Enable Settings (leave set to 31)
Serial Command: "E"
74
4.3
Averaging Time
8-bit byte
Averaging Time (aka DIP Average)
Serial Command: "K"
75
4.4
Measurement Units
8-bit byte
Measurement Units
Serial Command: "U"
76
4.5
Reset Length
8-bit byte (Write Only)
Length Reset - set to 1 to reset the length
Serial Command: "R"
77
4.6
Material Present
Mode
8-bit byte
Material Present Input Mode Setting
Serial Command: "S"