TECHNICAL SPECIFICATIONS
Rated voltage:
220-240V~
Rated current:
2.0A
Rated frequency:
50Hz
Lamp power:
MAX 10W
Climate class:
N/ST
Refrigerant:
R600a(82g)
Protection against electrical shock:
I
Insulation blowing gas:
CYCLOPENTANE
Climate class:
-
Extended temperate (SN): 'this refrigerating appliance is intended to be used at ambient temperatures
ranging from 10°C to 32 °C';
-
Temperate(N): 'this refrigerating appliance is intended to be used at ambient temperatures ranging from
16 °C to 32 °C';
-
Subtropical (ST): 'this refrigerating appliance is intended to be used at ambient temperatures ranging from
16 °C to 38 °C';
-
Tropical(T): 'this refrigerating appliance is intended to be used at ambient temperatures ranging from 16 °C
to 43 °C';
Note:
More data information, please scan the QR code on the energy label.
TROUBLESHOOTING
Symptom
Cause
Solution
The appliance does not
work.
There is no power supply.
Verify that the appliance is connected to the
plug.
The fuse
doesn’
t work.
Replace the fuse.
The appliance makes a
lot of noise.
The appliance is too close to the wall,
or is not stable, or the accessories
inside the refrigerator are placed in
wrong position.
Stabilize the base of the refrigerator by
adjusting the position of feet, take away the
device off the wall, place correctly the
accessories inside the refrigerator.
The appliance doesn’t
cool enough.
The door is too often opened or was
left opened for a long time.
Close the door and do not open it too much
frequently.
The refrigerator is too close to the
wall.
Take away the device off the wall for the
ventilation.
The refrigerator is too full.
Remove food of the device.
The temperature is badly adjusted.
Turn the knob of regulation of temperature
on
“3” or more
.
There are smells in the
appliance.
Food becomes obsolete inside the
refrigerator.
Throw away the obsolete food and wrap
the other.
The inside of the device needs to
be cleaned.
Clean the inside of the refrigerator.
The following symptoms are not breakdowns:
•
The noise of the cooling liquid which circulates in pipes can be heard, it is normal.
•
The humidity on the surface outside of the device during the wet seasons is not a problem of the device;
you just need to wipe it with a dry soft cloth.
•
The compressor and the condenser can warm more during the periods of strong heat.
•
The frame of the door is a bit hot; it means that the condenser works to evacuate the humidity of air.
GUARANTEE AND CUSTOMER SERVICE
Before delivery our devices are subjected to rigorous quality control. If, despite all care, damage has occurred
during production or transportation, please return the device to your dealer. In addition to statutory legal rights,