Installation Instructions for Wi-Q Technology™ EXQ Exit Hardware Trim
BEST
a Product Group of dormakaba USA Inc.
14
Installing the exit hardware and trim
13
Route sensor wires
Use the following table to determine sensing wire
functions:
1 Pull wires from the sensor harness, door position
switch, latchbolt switch, and touchbar switch to the
top of the device head as shown in Figure 23.
Note:
For Precision 2300, Sargent 8800, or any Von
Duprin application without RQE, pull the door position
switch and sensor harness wires into the battery bracket
area rather than the device head.
Note:
For Von Duprin applications with RQE, touchbar
switch wires must be re-routed into the device head in
such a way as to avoid any pinching or contact with
moving parts. The sensor harness can be routed into the
head area through any suitable hole in the chassis.
2 Cut the wires to the appropriate length (that is,
remove the excess to leave minimal slack after the
spliced connections).
3 Strip the wire ends for connection using the butt-
splices.
4 Make wire connections as detailed in Figure 24 or Fig-
ure 25 using the butt-splices (provided).
Note:
For Sargent devices, connect the door position
switch to the two white sensor harness wires.
Note:
In the case of unused wires, be sure to cover the
ends with electrical tape.
Wire function
Colors
No. of
wires
Touchbar monitoring (RQE)
Orange and tan
2
Door sensing
White
2
Latchbolt sensing
Red and blue
2
Figure 23 Pulling sensor harnesses to the top of the
device head
Pull sensor
wires to top of
device head
(shaded area)
Wire entry from
trim for vertical
rod (2200, 2700,
2800) device
Wire entry from
trim for rim
(2100) device
Red
Violet
NO
Blue
Blue
COM
Wht
Wht
Red
NC
Not used
Wht
Wht
Org
Org
NC
Tan
Tan
COM
Latchbolt
switch
EXQ T
r
im
Doo
r
positio
n
switch
To
u
chba
r
switch
Yellow
NO
Not used
Figure 24 Schematic diagram for connecting Precision
sensor harness wires
Sensor
harness
Butt
splices
NO
= Normally Open
NC
= Normally Closed
COM
= Common