45
1) Level switch;
11) Pressure regulating
2)
Thermostat;
valve;
3) Minimum tank capacity:
12) Regulating valve BY-PASS;
pump flowX4;
13) Outlet;
4) Watertight bulkheads on the bottom;
14) Pressure gauge;
5) Suction line
15) Pulsation dampener;
minimum dia. 47mm for C3006
16) By-pass line;
minimum dia. 33mm for CK3003;
17) tank feed;
6) Inlet filter;
18) Section valve to by-pass the flow
7) Pressure switch to control
when starting the pump
inlet;
3/4” for pumps CK 3003
8) Suction collector with
1” for pumps C 3006
minimum diameter 33mm;
19) Minimum dia. 25mm;
9) Safety valve;
20) Minimum dia. 18mm.
10) Safety valve BY-PASS;
4.5 ERRORS TO AVOID
1) Avoid for not having “siphon” effect
2) Avoid to install elbows 90°
3) Avoid diameters reductions;
4) Never connect the by-pass line with return on the inlet line.