7
Wire
Color
Task
Remarks
DC type solenoid - 9V-12V DC Latch - for pressure management
according to flow-rate
RED
To be connected to the
solenoid's RED wire
This wire is joint together with
the solenoid's RED wire in the
controller's black cable
BLACK
To be connected to the
solenoid's BLACK wire
This wire is joint together with
the solenoid's BLACK wire in
the controller's black cable
DC type solenoid - 9V-12V DC Latch - for pressure management
according to time interval
RED
To be connected to the
solenoid’s BLACK wire
This wire is joint together with
the solenoid's BLACK wire in
the controller's black cable
BLACK
To be connected to the
solenoid's red wire
This wire is joint together with
the solenoid's RED wire in the
controller's black cable
Water meter
RED
Connect one of the water-
meter's pulse wires to one of
the controller's RED wires
There is no polarity significance
in this connection
RED
Connect the other water-
meter's pulse wires to one of
the controller's RED wires
There is no polarity significance
in this connection
Flow switch
(or rain sensor for irrigation applications)
YELLOW
Cut the YELLOW loop and
connect one of the flow
switch wires to one of the
controller's yellow wires.
There is no polarity significance
in this connection
YELLOW
Connect the other flow switch
wire to one of the controller's
YELLOW wires.
There is no polarity significance
in this connection
Flow Switch/Rain Sensor:
Flow switch can be used with the time controlled pressure
management application for switching to the high pressure setting in
case of a high demand for water, i.e. in case of fire.
Wiring Table:
The controller is supplied with the following wires connected to its
terminal strip: