Mynute Green C.S.I. E - R.S.I. E
24
Parameter
Symbol
Mynute
Green
12 R.S.I. E
Mynute
Green
15 R.S.I. E
Mynute
Green
25 R.S.I. E
Mynute
Green
35 R.S.I. E
Unit
Seasonal space heating energy efficiency class
-
A
A
A
A
-
Water heating energy efficiency class
-
-
-
-
-
-
Rated heat output
Pnominal
12
15
25
34
kW
Seasonal space heating energy efficiency
ηs
93
93
92
93
%
Useful heat output
At rated heat output and high-temperature regime (*)
P4
11,7
14,6
24,5
33,7
kW
At 30% of rated heat output and low-temperature
regime (**)
P1
4,0
4,9
8,0
11,3
kW
Useful efficiency
At rated heat output and high-temperature regime (*)
η4
88,6
88,7
88,8
88,0
%
At 30% of rated heat output and low-temperature
regime (**)
η1
99,1
98,7
96,4
98,2
%
Auxiliary electricity consumption
At full load
elmax
34,0
32,0
40,0
60,0
W
At part load
elmin
11,9
11,3
13,7
19,7
W
In Stand-by mode
PSB
2,4
2,4
2,4
2,4
W
Other parameters
Stand-by heat loss
Pstby
58,0
49,0
58,0
69,0
W
Pilot flame energy consumption
Pign
-
-
-
-
W
Annual energy consumption
QHE
22
28
48
63
GJ
Sound power level, indoors
LWA
49
48
51
54
dB
Emissions of nitrogen oxides
NOx
23
29
27
28
mg/ kWh
For combination heaters
Declared load profile
-
-
-
-
Water heating energy efficiency
ηwh
-
-
-
-
%
Daily electricity consumption
Qelec
-
-
-
-
kWh
Daily fuel consumption
Qfuel
-
-
-
-
kWh
Annual electricity consumption
AEC
-
-
-
-
kWh
Annual fuel consumption
AFC
-
-
-
-
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).