5
GENERAL
3 DESCRIPTION OF THE
APPLIANCE
B
IDRA MS
solar storage cylinders come in capacities
of 200, 300, 430 and 550 litres, and are designed for
integration in solar domestic hot water production systems
heated by
B
solar collectors.
The most important technical features of these solar
storage cylinders are:
- The storage cylinder and coil are specially designed
and shaped for optimum performance in terms of
stratification, heat exchange and replenishment times
- Internal glazing, bacteriologically inert, to ensure the
maximum hygiene of treated water, reduce limescale
deposits and make cleaning operations easier
- CFC-free polyurethane insulation and an elegant
external casing reduce heat loss and improve
efficiency
- Temperature sensor and power cables are all
internally routed
- A flange is provided for easy cleaning and
maintenance of the anti-corrosion magnesium anode.
B
IDRA MS
solar storage cylinders can be equipped
with a special solar controller for easy integration in
B
solar water heating systems.
4 IDENTIFICATION
B
IDRA MS
storage cylinders are identified by:
Data plate
This lists the technical specifications and performance
of the product.
Beretta Caldaie
Via Risorgimento, 13
23900 Lecco (LC)
Beretta Caldaie
Via Risorgimento, 13
23900 Lecco (LC)
INTERACUMULADOR SOLAR
Modelo
N° Fabric.
Código
Año
Pressão máxima de exercício
Alimentaçcao eléctrica
bar
V-Hz
Capacidade do termoacumulador
l
T067659EPE02
Conexión a tierra obligatoria - Ligação á terra obrigatória - Obligatory ground connection
W
Potência eléctrica consumida
Potência consumida max.pela serp.sup. [T° Primário 80°C]
kW
Caudal especifico sup. [∆T 35°C]
l/1'
TERMOACUMULADOR SOLAR
Ano
Potencia absorbida max.serp.sup. [T° Primário 80°C]
Presión máxima de funcionamiento
Capacidad del interacumulador
Potencia eléctrica absorbida
Alimentación eléctrica
m
2
Superficie serpentín superior
Superfície serpentina superior
Superficie serpentín inferior
Superfície serpentina inferior
m
2
kW
Pot. cons. max.pela serp.sup.
N° Fabric.
Pot. absor. max.serp.sup.
Modelo
m
2
Sup. serpentín inf.
Sup. serpentina inf.
SOLAR STORAGE CYLINDER
Model
Serial number
Code
Year
Power absorbed by top coil (T° primary 80°C)
Domestic Hot Water production - top coil
Maximum working pressure of storage cylinder
Storage cylinder capacity
Electrical consumption
Power supply
Top coil heat exchange surface area
Bottom coil heat exchange surface area
Bottom coil heat exch. surf. area
Serial number
Model
Power absorbed by top coil
Serial number plate
This specifies the serial number and model.
b
If these plates or any other means of clearly
identifying the product are defaced, removed
or lost, proper installation and servicing may be
rendered difficult.
5 SYSTEM LAYOUT
1
2
3
4
5
6
7
11
10
9
8
1
Magnesium anode
2
Storage cylinder
3
Temperature gauge
4
Sleeve for electric heating element (not supplied)
5
Coil
6
Flange cover
7
Cylinder inspection flange
8
Sensor socket
9
Insulation
10
Cover
11
Plug for anode inspection and lifting
Summary of Contents for IDRA MS 200
Page 2: ...2...