7
GENERAL
7 WATER CIRCUIT
TYPICAL WATER SYSTEM SCHEMATIC
Solar regulator
°C
M
10
10
10
6
7
9
8
12
11
13
PS
5
16
2
R
M
4
3
UAC
EAF
1
1
9
8
10
10
10
10
7
15 14
17
19
PR
10
10
16
SB1
SCo
Water control system
1
Solar collector
2
Collector temperature sensor socket
3
Manual bleed valve
4
Vent cock
5
Vent valve
6
Pressure gauge
7
Safety valve
8
Drain
9
Expansion vessel
10
Disconnect valves
11
Temperature gauge
12
Flow regulator
13
Flow meter
14
Pressure reducer
15
Water softener filter
16
Non-return valve
17
Thermostatic mixer valve
18
Solar storage cylinder
19
DHW recirculation temperature sensor
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
M
Collector outlet
R
Collector return
PR
DHW recirculation pump
PS
Solar collector circuit pump
SB1
Storage cylinder bottom temperature sensor
SCo
Collector probe
Note! The above schematic is purely indicative.
b
B
IDRA MS
storage cylinders are delivered without a boiler heating pump. A suitably rated pump must be
provided and installed separately. Flow rate from the solar collector circuit depends on the type and number of
collectors installed. For further information, consult the manual for the collectors.
b
The domestic hot water system MUST INCLUDE an expansion vessel, safety valve, automatic vent valve and
storage cylinder drain cock.
b
Safety valves must be connected to a suitable collection and drain system. The manufacturer declines all
responsibility for damage caused by water escaping from safety valves.
b
The choice of system components and the method of their installation are left up to the heating engineer installing
the system. Installers must use their expertise to ensure proper installation and functioning in conformity to all
applicable legislation.
b
Circuits filled with anti-freeze must be fitted with water disconnectors.