Installing the device
34
Connection terminal for the multi-function
connection
A window switch can be connected to the multi-
function connection. The extractor hood fan is then
only operational when the window is open.
The control cable must be routed from the window
switch to the connection terminals for the multi-
function connection in the extractor hood.
The connection terminals for the multi-function
connection are marked "Window switch" in the
extractor hood.
In order to connect the control cable, the control
cable's two wires must be connected to terminals 1
and 2 for the multi-function connection in the
extractor hood.
Connection of the multi-function connection is
described in the following section.
For this step, a small standard screwdriver is
required for the connection terminals in the berbel
extractor hood.
¾
Route the window switch control cable to the
extractor hood.
¾
Make sure that the terminals for the multi-function
connection in the extractor hood are accessible.
¾
Pull the control cable through the cable passage
hole to the extractor hood's control box.
The connection terminals for the multi-function
contact and the wall box contact are located in the
upper corner of the control box. The connection
terminals are marked "Window switch" and "BMK"
or "Wall box". The terminal pairs are labelled "1"
and "2".
Proceed as follows to connect the control cable:
¾
Unscrew the screw for "Window switch"
terminal 1.
¾
Take up offset wire 1 of the control cable.
¾
Guide wire 1 into terminal 1.
¾
Make sure that the control cable's wire connector
sleeve is completely in the terminal.
¾
Make sure that the control cable's insulation is not
in the terminal.